RJ45 Ports

The IR807 supports two ISOLATED RS232 ports which conforms to EIA-561 standard. RS232 pin out is
shown in the following figure applies to serial 0 and serial 1, but the directions of the DTE and DCE port are
opposite.
The RS232 DTE pin out applies to both serial 0 and serial 1. This port is not shared with the Console port.
Note: The RS232 DTE pin out is different from the Cisco standard Console/Auxiliary port.
The following figure shows the characteristics of the S0 and S1 ports:
The following table shows the S0 and S1 Details
Pin Number
1
2
3
4
5
6
7
8
Description
Abbreviation
DCE Ready, Ring
DSR/RI
Indicator
Received Line
DCD
Signal Detector
DTE Ready
DTR
Signal Ground
COM
Received Data
RxD
Transmitted Data
TxD
Clear To Send
CTS
Request To Send
RTS
Cisco IR807 Industrial Integrated Services Router Hardware Installation Guide
DTE
DCE
<—
—>
<—
—>
—>
<—
<—
—>
—>
<—
<—
—>
—>
<—
RJ45 Ports