Starting Problems - Toro Pro Force 44552TE Service Manual

Debris blower
Table of Contents

Advertisement

Starting Problems

Problem
The starter solenoid clicks, but the
starter does not crank
Nothing happens when you attempt to
start the engine using the key switch
Models 44552, 44552TE, and 44553
– Nothing happens when you attempt
to start the engine using the wireless
remote
Troubleshooting: Starting Problems
Possible Cause
The battery charge is low
The battery is discharged or damaged
The battery cables are loose or
corroded
The ground connection is loose or
corroded
The wiring at the starter motor is
damaged
The starter solenoid or starter motor is
damaged
The battery is discharged or damaged
The battery cables are loose or
corroded
The ground connection is loose or
corroded
A fuse is damaged
A relay is damaged
The key switch is damaged
The wiring to the start circuit
components is corroded, loose, or
damaged
The wiring at the starter motor is
damaged
The starter solenoid or starter motor is
damaged
The batteries in the wireless remote are
discharged or installed improperly
The association between the wireless
remote and the control module has
been lost
The wireless remote or control module
is damaged
Page 3–6
Corrective Action
Charge the battery
Charge and test the battery
Replace the battery if necessary
Clean and secure the battery cables
Clean and secure the ground
connections at the engine block
Repair or replace starter wiring
Refer to the Kohler Command Pro
CH740 Service Manual for starter
solenoid and starter motor information.
Charge and test the battery
Replace the battery if necessary
Clean and secure the battery cables
Clean and secure the ground
connections at the engine block
Test the fuse and replace it if necessary
F–1 (7.5 A), F–2 (7.5 A), F–3 (15 A),
and/or F–4 (2 A) if necessary; refer to
Fuses in Chapter 5 – Electrical System
Test the start relay and main power
relay and replace them if necessary;
refer to Component Testing in Chapter
5 – Electrical System
Test the key switch and replace it if
necessary; refer to Component Testing
in Chapter 5 – Electrical System
Clean, secure or repair/replace the
circuit wiring; Refer to the Electrical
Schematics in Appendix A
Test the circuit wiring and replace it as
necessary
Refer to the Kohler Command Pro
CH740 Service Manual for starter
solenoid and starter motor information.
Attempt to start the engine with the
key switch. If the engine starts,
troubleshoot the wireless remote as
follows:
Test the batteries and replace them if
necessary
Make sure the batteries are properly
installed; refer to Wireless Remote in
Chapter 5 – Electrical System
Re-establish remote control-to-base
unit communication; refer to the
machine Operator's Manual
Replace the wireless remote
Pro Force® Debris Blower
18237SL Rev A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro force 44553Pro force 44552Pro force 44554

Table of Contents