Testing the Hour Meter
Electrical System: Testing the Electrical Components
g233942
1.
Control tower
The hour meter used on the Pro Force Debris Blower records the amount of
time that the engine is running.
1. Park the machine on a level surface and stop the engine.
2. Disconnect the battery negative (-) cable at the battery.
3. Disconnect the wire harness connector from the hour meter and remove the
hour meter from the control tower if necessary.
4. Connect the positive (+) terminal of the hour meter to the positive (+) terminal
of a 12 VDC power source.
5. Connect the negative (-) terminal of the 12 VDC power source to the other
terminal of the hour meter.
6. The hour meter should move 1/10 of an hour in 6 minutes.
7. Disconnect the voltage source from the hour meter.
8. Replace the hour meter if necessary.
9. If the hour meter tests correctly and a circuit problem still exists, check the
wire harnesses; refer to
10. Install the hour meter and connect the wire harness after testing.
11. Connect the battery negative (-) cable at the battery.
Figure 24
2.
Hour meter
Appendix A (page
Page 5–20
A–1).
Pro Force® Debris Blower