Troubleshooting; Starting Problems - Toro ProForce Debris Service Manual

Table of Contents

Advertisement

PRELIMINARY – For Toro Distributor and Toro Company use only.

Troubleshooting

Remove all jewelry, especially rings and
watches, before doing any electrical trouble-
shooting or testing. Disconnect the battery
cables unless the test requires battery voltage.

Starting Problems

Problem
Starter solenoid clicks, but starter will not crank.
Nothing happens when start attempt is made.
ProForce Debris Blower
CAUTION
For effective troubleshooting and repairs, there must be
a good understanding of the electrical circuits (see
Chapter 7 − Electrical Diagrams) and components used
on this machine.
Possible Causes
Battery is discharged.
Battery cables are loose or corroded.
Wire harness ground cable is loose or corroded.
Wiring at starter is faulty.
Starter solenoid is faulty.
Starter is faulty.
Battery is discharged.
Wiring to the start circuit components is loose,
corroded or damaged (see Electrical Schematic in
Chapter 7 − Electrical Diagrams).
Battery cables are loose or corroded.
Wire harness ground cable is loose or corroded.
Main fuse (15 amp) is loose or faulty.
Fusible link is faulty.
Ignition switch is faulty.
Starter solenoid is faulty.
Operator remote control or remote control module is
faulty.
Page 4 − 5
Electrical System