Adsorber Replacement - HELIX 9600 Installation, Operation And Maintenance Instructions

High voltage compressor
Table of Contents

Advertisement

Scheduled Maintenance

Adsorber Replacement

HOLD WITH 1 1/8 INCH WRENCH
TURN WITH 1 3/16 INCH WRENCH
TO LOOSEN
5-2
Part Number 8040437, Revision 104, 06/12/2007, ECO Number 18068
Use the following procedure to change the adsorber every three years.
1. Set the System Circuit Breaker, on the rear of the 9600
Compressor, to the OFF position.
2. Remove the 4 screws which secure the rear panel to the
Compressor and remove the rear panel.
NOTE: Use two wrenches in Step 3 to prevent loosening the body of the
coupling.
3. Using a 1-3/16 in. wrench, and a 1-1/8 in. wrench, as shown in
Figure
5-1, disconnect the two self sealing coupling connectors
quickly to minimize helium leakage.
This 1 1/8 (or 1) in. wrench
holds the coupling in a sta-
tionary position.
Figure 5-1: Disconnecting Self Sealing Couplings
4. Using a 7/16 in. (11mm) wrench, remove the adsorber mounting
bolt as shown in
Figure
This 1 3/16 in. wrench
is used to turn the self
sealing coupling con-
nector.
TO TIGHTEN
TURN WITH 1 3/16 INCH WRENCH
HOLD WITH 1 INCH WRENCH
5-2.
©2007 Helix Technology Corporation