OCTAVIA
Edition 08.96
S00.5109.50.20
Ignition System
Testing ignition transformer
Special tools, testers and aids required
♦ Hand-held multimeter V.A.G 1526 A or
multimeter V.A.G 1715
♦ Adapter cable set V.A.G 1594 A
Test procedure
-
Unplug the connector and ignition cable from
the ignition transformer (N152).
K -
Test the primary resistance between termi-
nals 1 and 15.
Specification: 0.5...1.2
-
Test the secondary resistance between ter-
minals 4 and 15.
Specification: 3...4 k
If the specifications are not achieved:
-
Replace the ignition transformer
28-1, item 1.
Testing ignition transformer output
stage
Special tools, testers and aids required
♦ Test box V.A.G 1598/22
♦ Hand-held multimeter V.A.G 1526 A or multi-
meter V.A.G 1715
♦ Diode test lamp V.A.G 1527
♦ Adapter cable set V.A.G 1594 A
♦ Current flow diagram
Test conditions
l Hall sender o.k.
l Ignition transformer o.k.
28
page
------------ 28-7 ------------