Delta HPH-20KA01KAT User Manual page 33

Continuous 400 – 1000 vdc
Table of Contents

Advertisement

Delta Electronics. Inc.
Note 6.2: Check Sum value is the summation of "1" signal calculated by byte 0 to 7.
Example:
"Master IP is 01, Power On", Byte 0~7 are "0x01-0x41-0x00-0x00-0x00-0x00-0x00-0x00".
There are three "1" in this command, so checksum is 3.
Note 6.3: Use 9600bps, 8 data bits, no parity, 1 stop bit (9600/8-N-1).
Note 6.4: PSU state Byte 4(Warning) and Byte 5(Alarm) value refer to table 4.1
Table 6.5 Value definition (Translate decimal to hexadecimal for utilizing)
Command
CV Mode
CC Mode
CP Mode
Master/Slave
A/Ri Offset
A/Vo Offset
A/Io Offset
Terminating Resistor
Set Point
Pause Time
Energy Mode
Arc Function
Parallel Number
Max Power
Max Current
Max Voltage
Ramp Time
Target Life
Delay time
Arc Voltage
Arc Density
Arc Number
Ignition
Byte3
Byte4
4 to 25 for 40 to 250us, Scale: 10us
1 to 99999 for 1 to 99999kJ, 0: OFF
0 to 1500000 for OFF to 15000.00kWh, 0: OFF
Byte5
0 to 1000 for 0 to 1000V
0 to 500 for 0~50.0A
0 to 200 for 0 to 20.0kW
Master: 00, Slave: 01
Plus: 00, Minus: 01
Plus: 00, Minus: 01
Plus: 00, Minus: 01
IP for
1
to 16
1 to 10 for 1 to 10s
OFF: 0, ON: 1
1 to 16 for 1 to 16 sets
20 to 200 for 2 to 20kW
50 to 500 for 5 to 50A
500 to 1000 for 500 to 1000V
5 to 200 for 50 to 2000ms
0 to 5 for 0 to 5us
25 to 200 for 25 to 200V
0 to 99 for 0 to 99 times/s
0 to 999 for 0 to 999 times
10 to 19 for 1000 to 1900V
HPH- 20KA01KAT
Byte6
0 to 99 for 0 to 9.9%
0 to 99 for 0 to 9.9%
0 to 99 for 0 to 9.9%
OFF: 0, On: 1
29