Process And Monitor Function; Mechanical Specification - Delta HPH-20KA01KAT User Manual

Continuous 400 – 1000 vdc
Table of Contents

Advertisement

Delta Electronics. Inc.

3.4. Process and Monitor Function

Item
Max. Power
Max. Current
Max. Voltage
Ignition Mechanism
Ramp Time
Set Point
Energy Mode
Target Life Mode

3.5. Mechanical Specification

The outward appearance, cooling specification for minimum CFM Requirement, and I/O ports
of Delta "HPH-20KA01KAT" power supply are described as below:
Item
Physical Dimension
Weight
Cooling
Noise
AC Input Connector
DC Output Connector
User Port
Host Port
Parallel Bus
Table 3.4 Adjustable function parameters for User
Specification
2 to 20 kW
5 to 50 A
500 to 1000 V
1000 to 1900 V
50 to 2000 ms
1 to 10 s
1 to 99999 kJ
1 to 15000 kWh
Table 3.5 Mechanical specification
Description
482.6 mm (W) x 132.5 mm (H) x 600 mm (L)
19" (W) x 5.2" (H) x 22.0" (L)
19" 3U
38.7 kg
Fan cooling
Noise generated by this unit under 70 dB (A) at a 1m distance in 25
˚C ambient temperature
4 pin terminal block
3 pin terminal block
Analog I/O: 15-pin female D-sub
Digital I/O: 9-pin female RS232 and RS485
8-pin RJ46
HPH- 20KA01KAT
Description
Power will be constrained within
the value of setting prior to the
set point of regulation.
Current will be constrained
within the value of setting prior
to the set point of regulation.
Voltage will be constrained
within the value of setting prior
to the set point of regulation.
A voltage up to 1900 V is
adjustable for igniting the
system.
A ramp up to set point is
adjustable for a soft start
mechanism.
Monitoring if the output reaches
the setting of regulation within
the setting of period.
Monitoring if the output energy
reaches the setting of energy.
Monitoring if the output energy
reaches the setting of kWh.