Program Examples - Mitsubishi Electric FX-1PG User Manual

Pulse generator unit
Table of Contents

Advertisement

FX-1PG/FX
-1PG PULSE GENERATOR UNIT
2N
10
10.

PROGRAM EXAMPLES

10.1
Program Examples
< Fixed length cutting unit for a long material >
Supply reel
Feed roll
Powder
brake
PG
SM
Servo
amplifier
Cycle
stop
Start
Stop
X007
X001
FP
RP
PC
FX-1PG
FX
-1PG
2N
Data access unit FX-10DU
Fixed length feedrate setting
: 100 to 9,999 mm
Operating velocity setting
: 314 to 3,140 cm/min
• Long material rolled up around a reel is supplied at a fixed
Cutter
feedrate by the servo motor, and cut into fixed lengths by a
X002
Y000
cutter.
• The cutter is driven by the output Y000 from the PC. The limit
X003
switches X003 and X002 are provided to confirm the operation
and return.
• When the start button X007 is pressed, continuous operation is
started. When the cycle stop button X001 is pressed, the
material is cut and the operation is stopped.
HA-FE63
• When the STOP input of the PGU is turned on, the motor
immediately decelerates and stops. When the start button is
MR-J60A
pressed again, the remaining distance is move and the
operation is continued.
MR-RB064
Start X007
Feed operation
Cutter Y000
Cutter operation X003
Cutter return X002
Cycle stop X001
EXAMPLES PROGRAM
STOP input
Operation is interrupted.
Stop