Omron SYSMAC 3G8F7-CLK13-E Operation Manual page 90

Controller link support boards for pci bus
Table of Contents

Advertisement

Detailed Error Information
70
Error
Macro name
code
34
---
35
---
36
---
37
---
38
---
39
---
40
---
41
---
42
---
43
---
44
---
45
---
46
---
47
---
48
---
49
---
50
---
51
---
52
---
53
---
54
---
55
---
56
---
57
---
58
---
59
---
60
---
61
---
62
---
63
---
64
---
65
---
66
---
67
---
68
---
69
---
Section 4-3
Meaning
Network busy; cannot execute.
Reception buffer overflow
Data size error
FINS header error
Reception timeout (no receive data)
Invalid SID setting
Version is not supported; impossible to
execute.
Wrong setting in routing tables; cannot
reach final network
Routing table error
Allowed number of gateways exceeded
Version already in locked state and can't
change.
Attempted to make header to response.
Attempted to make response to com-
mand that requires no response.
Could not make event object to be used
for send data notice.
Could not make list object to be used to
receive data.
Failed in standby process of exclusive
control of shared memory.
Failed in mapping of shared memory.
Name of object is too long.
Attempted to release unused unit
address.
Unexpected error occurred.
Failed to initialization of shared memory.
Failed in attachment to shared memory.
Number of units (units) simultaneously
usable exceeded.
Send destination unit does not existence.
Could not notify data transmission.
Exit from receive standby due to abnor-
mal end of other process.
Failed in receive standby.
All reserved area of network handle is
fully used.
Incoming data is not received yet.
Invalid Windows message type
Failed in message notice.
Invalid prototype
Buffer is too short.
Invalid Windows handle
Failed in beginning thread for sending
message.
Message registration duplication error