TROUBLESHOOTING

Problem:
Possible cause:
Door does not lock
No power
Door locks, but can be
Poor contact between
easily forced open
electromagnet and
armature plate
Incorrect voltage
setting
Delay in door releasing
A secondary diode was
installed across the
electromagnet

REGULAR MAINTENANCE

• Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-
abrasive, non-corrosive cleaner.
• Apply a light coat of a silicon lubricant to prevent rust. Wipe away the excess.
• Check that the armature plate is securely attached to the door, yet can pivot slightly around the
armature screw.
• Check that the electromagnet is securely attached to the door frame.
UL CERTIFICATION
E-941SA-600 and E-941SA-1200 electromagnetic locks conform to UL/10B "Fire Tests of Door
Assemblies" and UL/10C "Positive Pressure Fire Tests of Door Assemblies" for swinging door
assemblies. They are also classified in accordance with the Uniform Building Code standard 7-2.

WARRANTY:

ENFORCER Electromagnetic Locks are warranted against defects in
material and workmanship while used in normal service for a period of one (1) year from the
date of sale to the original customer. Our obligation is limited to the repair or replacement of any
defective part if the unit is returned, transportation pre-paid, to SECO-LARM.
NOTICE
The information and specifications printed in this manual are current at the time of publication.
However, the SECO-LARM policy is one of continual development and improvement. For this reason,
SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not
responsible for misprints or typographical errors.
Copyright © 2003 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced
or copied, in whole or in part, without the written permission of SECO-LARM.
SECO-LARM
SECO-LARM
SECO-LARM
U.S.A., Inc.
U.S.A., Inc.
U.S.A., Inc.
SECO-LARM
SECO-LARM
®
U.S.A., Inc.
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Page 4
Solutions:
• Check to make sure the wires are
securely tightened to the terminal block
• Check that the power supply is connected
and operating
• Make sure the lock switch is wired
correctly
• Make sure the electromagnet and
armature plate are properly aligned
• Make sure the contact surfaces of the
electromagnet and armature plate are
clean and free from rust
• Check the power leads with a meter, and
make sure 12VDC or 24VDC is present
• The electromagnet is fitted with a metal
oxide varistor to prevent interference, so
do not install a secondary diode