Troubleshooting; Maintenance - SECO-LARM E-946FC-600Q Manual

Electromagnetic gate locks with face or surface mounting
Table of Contents

Advertisement

SECO-LARM Electromagnetic Gate Locks with Face or Surface Mounting

Troubleshooting:

The gate does not lock.
The gate locks, but can be
easily forced open.
There is a delay in the
gate releasing.

Maintenance:

1. Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and
non-abrasive, non-corrosive cleaner.
2. Apply a light coat of a silicon lubricant to both contact surfaces and wipe away the excess to
prevent rust.
3. Check that the armature plate is securely attached to the door, yet can pivot slightly around the
armature screw.
4. Check that the electromagnet is securely attached to the gate or post.
LIMITED LIFETIME WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used
in normal service for the lifetime of the product. SECO-LARM's obligation is limited to the repair or replacement of any defective part
if the unit is returned, transportation prepaid, to SECO-LARM. Under no circumstances will SECO-LARM be responsible for any
costs or charges for removal, installation, or reinstallation. This Warranty is void if damage is caused by or attributed to acts of God,
physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any
other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in
material and workmanship. The sole obligation of SECO-LARM, and the purchaser's exclusive remedy, shall be limited to
replacement or repair only at SECO-LARM's option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or
consequential personal or property damages of any kind to the purchaser or anyone else. This limited lifetime warranty is for
products sold and installed in the United States and Canada. For all other countries the warranty is 1 (one) year.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change
specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part,
without the written permission of SECO-LARM.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
8
• Check that the wires are secure.
• Check that the power supply is connected and operating.
• Check that the unit is wired correctly.
• Check that the electromagnet and armature plate are properly aligned.
• Check that the contact surfaces of the electromagnet and armature
plate are clean and free from rust.
• Check the power leads with a meter, and make sure the correct
voltage is present.
• Make sure that power supply is 12/24 VDC. Do not connect the
electromagnet to VAC.
• The electromagnet is fitted with a metal oxide varistor to prevent
interference, so do not install a secondary diode.
Website: www.seco-larm.com
E-mail: sales@seco-larm.com
SECO-LARM U.S.A., Inc.
MiE-946FC-xxxQ_140610.docx
PITGW1

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-946fc-1k2q