Specifications; Roof Requirements - Dometic 57908.321 Installation Instructions Manual

Table of Contents

Advertisement

SPECIFICATIONS

A.
Table - Unit Data
Model No.
Nominal
Electrical
Capacity
Rating
(BTU HR)
Cooling
57908.321
7,180
120 VAC
60Hz. 1PH
57908.521
7,100
57912.531
11,000
57912.532
11,000
57915.331
13,500
57915.336
13,500
57915.531
13,500
57915.536
13,500
57915.541
13,500
57915.546
13,500
57915.741
13,500
57915.746
13,500
59516.331
15,000
59516.336
15,000
59516.531
15,000
59516.536
15,000
59516.731
15,000
59530.532
N/A
59530.536
N/A
520310.501
9,000
520315.501
13,500
520315.506
13,500
520316.501
15,000
520316.506
15,000
520300.501
N/A
600312.331
11,000
600315.331
13,500
600315.336
13,500
*
For wire length over 24 ft., consult the National Electrical Code for proper sizing.
** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences
people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.
B.

Roof Requirements

A 14-1/4" x 14-1/4" (±1/8") square opening (hereinafter referred to as "roof opening") is required for installing this
unit. This opening is part of the return air system of the unit and MUST be finished in accordance with NFPA 1192.
Roof construction with rafters/joists support frames on a minimum of 16 inch centers.
Minimum of 2 inches and maximum of 5-1/2 inches distance between roof to ceiling of RV.
Compressor
Compressor
Fan Motor
Rated Load
Locked
Rated Load
Amps
Rotor
Amps
Amps
6.9
36.0
2.5
6.6
34.0
2.5
8.0
53.0
2.5
12.1
59.0
2.5
11.4
58.0
2.5
12.1
59.0
2.5
12.1
59.0
2.5
12.1
59.0
2.5
11.3
62.0
2.5
11.3
62.0
2.5
12.0
58.0
2.5
12.0
58.0
2.5
11.5
50.0
2.5
12.7
60.0
2.0
11.5
50.0
2.5
11.5
50.0
2.5
13.3
62.0
2.0
8.0
53.0
2.5
7.8
53.0
2.0
7.8
49.0
3.0
10.3
62.0
3.0
10.3
62.0
3.0
13.2
79.0
2.8
13.2
79.0
2.8
7.8
49.0
3.0
9.5
53.0
3.5
12.4
60.0
3.5
12.4
60.0
3.5
Fan Motor
Refrigerant
Minimum
Locked
R-410A
Wire Size*
Rotor
(Oz.)
Amps
5.8
16.0
5.8
17.0
5.8
18.5
5.8
16.5
5.8
15.5
5.8
16.5
5.8
16.5
5.8
16.5
5.8
16.0
5.8
16.0
5.8
15.5
5.8
15.5
5.8
29.0
5.6
29.0
5.8
26.5
5.8
29.0
5.6
29.0
5.8
18.5
5.6
19.0
8.5
20.0
8.5
16.5
8.5
16.5
7.6
30.0
7.6
30.0
8.5
20.0
10.0
17.0
10.0
15.2
10.0
15.2
4
AC Circuit
Minimum
Protection
Generator Size**
***Installer
1 Unit / 2 Units
Supplied
20 Amp
2.5 kW / 4.0 kW
20 Amp
2.5 kW / 4.0 kW
20 Amp
2.5 kW / 4.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
15 Amp
3.5 kW / 5.0 kW
15 Amp
3.5 kW / 5.0 kW
20 Amp
2.5 kW / 4.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
15 Amp
2.5 kW / 4.0 kW
20 Amp
2.5 kW / 4.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW