Battery Charging - Ac Connections; Assembly Instructions - Schumacher INC-2405A Owner's Manual

Industrial series battery charger for 24-volt batteries
Table of Contents

Advertisement

Available languages

Available languages

7.5
Do not face the battery when making the final connection.
7.6
When disconnecting the charger, always do so in the reverse order of the
connecting procedure and break the first connection while as far away
from the battery as practical.
7.7
A marine (boat) battery must be removed and charged on shore. To
charge it onboard requires equipment specially designed for marine use.
8.

BATTERy CHARGING - AC CONNECTIONS

8.1
This battery charger is for use on nominal 100 - 240
volt circuits.
DANGER – Never alter AC cord or plug provided – if it
does not fit the outlet, have proper outlet installed by a
qualified electrician. Improper connection can result in
a risk of an electric shock.
8.2
Recommended minimum AWG size for extension
cords for battery chargers:
AC input rating,
amperes
At least
0
2
3
4
5
6
8
10
12
14
16
18
a
If the input rating of a charger is given in watts rather than in
amperes, the corresponding ampere rating is to be determined
by dividing the wattage rating by the voltage rating
example:
9.

ASSEMBLy INSTRUCTIONS

No assembly required.
a
But less
25
than
(7.6)
2
18
3
18
4
18
5
18
6
18
8
18
10
18
12
16
14
16
16
16
18
14
20
14
1250 watts/125 volts = 10 amperes
AWG size of cord
Length of cord, feet (m)
50
(15.2)
(30.5)
18
18
18
18
16
16
14
14
12
12
12
12
5
100
150
(45.6)
18
16
16
14
16
14
14
12
14
12
12
10
12
10
10
8
10
8
10
8
8
8
8
6
for

Advertisement

Table of Contents
loading

Table of Contents