Fd03 (Output Current (Real Time)); Fe36 (Analog Input Value Vi/Ii); Fe37 (Rx Input); Fe60 - Fe63 (My Monitor) - Toshiba TOSVERT VF-AS1 Series Function Manual

Ethernet/ip option unit
Hide thumbs Also See for TOSVERT VF-AS1 Series:
Table of Contents

Advertisement

3.2.4.11.

FD03 (Output current (real time))

The output current is read into 0.01% of units and by the hexadecimal number.
For example, when the output current of the rated current 4.8A inverter is 50% (2.4A), 0x1388
(hexadecimal number) is read.
Since the minimum unit is 0.01%,
0x1388 (Hex.) = 5000 (Dec.) * 0.01 = 50 (%)
Also about the following parameters, these are the same as this.
- FD05 (Output voltage(real time) ................................................... Unit: 0.01% (V)
- FD04 (Voltage at DC bus (real time) ............................................ Unit: 0.01%(V)
- FD18 (Torque) .............................................................................. Unit: 0.01% (Nm)*
* When the motor information connected to the inverter set to the parameter (f405 - f415), torque
monitor value "100%" is same as the rated torque of a motor in general.
3.2.4.12.

FE36 (Analog input value VI/II)

The value inputted into the VI/II terminal is read.
The value range is 0x0 to 0x2710 (0 to 100.00 %).
- Also about FE35 (RR Input), it is the same as this parameter.
3.2.4.13.

FE37 (RX Input)

The value inputted into the RX terminal is read.
The value range is 0xD8F0 to 0x2710(-100.00 to +100.00 %).
3.2.4.14.

FE60 - FE63 (My Monitor)

Refer to the function Manual (E6581335).
3.2.4.15.

FE14 (Cumulative run time)

The operated cumulative time is read by the hexadecimal number.
For example, when cumulative operation time is 18 hours, 0x12 (Hex) is read.
0x12 (Hex.) = 18 (Dec., hour)
3.2.4.16.

FE40 (Analog output (FM))

The output value of FM terminal is read.
The value range is set to 0 to 10000 (0x2710).
- Also about FE41 (AM terminal output monitor), it is the same as this parameter.
- 18 -
E6581581

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tosvert vf-ps1 seriesTosvert ipe001z

Table of Contents