Vent Filter - LG 6RWU0-05A Engineering Product Data Book

Ptac type (60hz/r410a)
Table of Contents

Advertisement

Mechanical accessories

2.11 Vent Filter

The Vent filter is used to filter the air flowing inside the
room when Air Ventilation is performed by means of the
ventilation lever.
Installation Procedure:
The Installation and servicing of the equipment should be
performed by qualified and experienced personnel only.
Before cleaning the vent filter, disconnect power to the unit
by unplugging the power cord at the wall outlet or subbase,
or disconnect power at the fuse box or circuit breaker. If
unit is operated with vent door closed, the vent filter does
not need to be cleaned.
1. Remove the cabinet front grille as described in Front
Grille Removal.
2. Remove the 4 screws securing the chassis to the wall
sleeve with a Phillips-Head screwdriver.
3. Slide the chassis out of the wall sleeve far enough so
that the vent filter is accessible as shown in Figure A.
4. Remove the vent filter by unscrewing the two screws at
the top of the filter and gently pulling the filter away from
the partition panel. Refer to Figure B.
5. Clean and replace the filter by reattaching the hook to
the bottom of the vent door and replacing the two
screws, slide the chassis back into the wall sleeve,
secure it in place with 4 screws and reinstall the front
cabinet.
Note:
Vent filter supplied as SVC Part not as an accessories
part. Vent Filter can requested by Part Number
5230A20016A
81
Figure A – Vent (Left side of unit)
Figure B – Vent Filter Removal
PTAC
6RWU0-05B
Accessories