Mechanical accessories

2.10 Vent Filter

Before cleaning the vent filter, disconnect power to the unit
by unplugging the power cord at the wall outlet or subbase,
or disconnect power at the fuse box or circuit breaker. If
unit is operated with vent door closed, the vent filter does
not need to be cleaned.
Cleaning the Vent Filter
1
Remove the front grille as described in front grille
Removal.
2
Remove the 4 screws securing the chassis to the wall
sleeve with a Phillips-Head screwdriver.
Note:
Vent filter supplied as SVC Part not as an accessories part.
Vent Filter can requested by Part Number 5230A20016B
76
Slide the chassis out of the wall sleeve far enough so
3
that the vent filter is accessible as shown in Figure A.
Remove the shipping screw from the ventilation door.
4
Remove the vent filter by unscrewing the two screws at
the top of the filter and gently pulling the filter away
from the partition panel. Refer to Figure B.
5
Wash the filter using lukewarm water below 40 °C
(104 °F). Reinstall the filter by reattaching the hook to
the bottom of the vent door and replacing the two
screws, slide the chassis back into the wall sleeve,
secure it in place with 4 screws and reinstall the front
cabinet.
PTAC
6RWU0-06A
Figure A
Figure B