LG 6RWU0-05A Engineering Product Data Book
LG 6RWU0-05A Engineering Product Data Book

LG 6RWU0-05A Engineering Product Data Book

Ptac type (60hz/r410a)

Advertisement

Quick Links

PTAC Type
(60Hz/R410A)
6RWU0-05A

Advertisement

Table of Contents
loading

Summary of Contents for LG 6RWU0-05A

  • Page 1 PTAC Type (60Hz/R410A) 6RWU0-05A...
  • Page 2: Table Of Contents

    PTAC Introduction Part 1 General information 1. Model line up ..................12 2. Nomenclature ...................13 3. Appearance..................14 4. List of functions ................15 5. Features ....................16 PTAC...
  • Page 3 Part 2 Product data 1 YA chassis ..................22 1.1 Features......................22 1.2 List of functions.....................23 1.3 Specifications....................24 1.4 Dimensions ....................30 1.5 Piping diagrams ....................31 1.6 Wiring diagrams....................33 1.7 Capacity tables .....................35 1.8 Electrical characteristics ................43 1.9 Operation range....................44 1.10 Sound level test method................44 2 Control Devices................45 2.1 Electronic Controls..................45 PTAC...
  • Page 4 Part 3 Design and installation 1 General installation procedure............51 2 Installation of unit................52 2.1 Safety precautions ..................52 2.2 Points of explanation about operations ............55 2.3 Selecting installation site for the unit .............55 2.4 Installation of unit...................56 2.5 Wall sleeve installation ..................58 PTAC...
  • Page 5 Part 4 Accessories 1 Controller accessories ..............65 1.1 Hard Wire kit ....................65 1.2 Wired Wall Thermostat Connection Kit ............67 2 Mechanical accessories ..............68 2.1 Control Panel Key Lock ................68 2.2 Outer Grille ....................69 2.3 Condensate Drain Kit ..................71 2.4 Leveling Legs ....................73 2.5 Sub Base ......................74 2.6 Lateral Duct Accessory System ..............76 2.7 Replacement Filter - 10 Pack ................79...
  • Page 6 Test condition of International Standards 6RWU0-05B Test condition of International Standards AHRI AHAM CLASSIFICATION 9306 5151 210/240 1861.1 DB°C(°F) 27.0 27.0 26.7(80) 26.7(80) 27.0 29.0 Indoor Cooling WB°C(°F) 19.5 19.0 19.4(67) 19.4(67) 19.0 19.0 Capacity DB°C(°F) 35.0 35.0 35.0(95) 35.0(95) 35.0 46.0 Outdoor...
  • Page 7: Introduction

    Packaged Terminal Air-Conditioners(PTAC) of LG is the best choice a customer can avail when it comes to a quiet environ- ment. Ultra quiet operation is the hallmark of these Air-Conditioners of LG. This range of units is suitable for Hotels and Healthcare applications.
  • Page 8 60Hz PTAC R410A 2016 Model Line UP 6RWU0-04A Jun,2016 60Hz PTAC R410A Spec Sheet Update Feb,2017 6RWU0-04B 60Hz PTAC R410A 2017 Model Line UP 6RWU0-05A Aug,2017 60Hz PTAC R410A Spec sheet update (add gross weight) Nov,2017 6RWU0-05B PTAC General information...
  • Page 9 6RWU0-05B Introduction Step by step air conditioner selection process (reference) Calculate or obtain the maximum heat load for the area to be air conditioned. Specifications Model features and functions Air-flow and temperature distribution Selection of the control system Remote Wall Thermostat Control Front Desk Control CAUTION 1.
  • Page 10 6RWU0-05B PTAC General information...
  • Page 11: Part 1 General Information

    Part 1 General information 1. Model line up ..................12 2. Nomenclature ..................13 3. Appearance ..................14 4. List of functions ..................15 5. Features ....................16 General information PTAC...
  • Page 12: Model Line Up

    Model line up 6RWU0-05B 1. Model line up Model names Capacity, kW(kBtu/h) Chassis 2.05(7) 2.64(9) 3.52(12) 4.4(15) UYC093ALEU1(LP093CDUC) UYC123ALEU1(LP123CDUC) UYC073ALEU1(LP073CDUC) Y4NZ09ANLD1 (LP093HDUC1) Y4NZ12ANLD1 (LP123HDUC1) UYC153ALEU1(LP153CDUC) UYH073ALEU1(LP073HDUC) UYC09EALE31(LP096CD3B) UYC12EALE31(LP126CD3B) UYH153ALEU1(LP153HDUC) UYH09EALE31(LP096HD3B) UYH12EALE31(LP126HD3B) PTAC General information...
  • Page 13: Nomenclature

    Fan Mode + Auto Restart + Evaporator Frost Control + 2kW~5kW (Universal Heater) Freeze Room Protection + 4-Way Cooling + Condensate Pump Look L: LG Brand Production type N: In house S: Outsourcing Chassis : A – YA chassis. Capacity Ex) 07 ->...
  • Page 14: Appearance

    Appearance 6RWU0-05B 3. Appearance Chassis Unit Models UYC073ALEU1(LP073CDUC) UYH073ALEU1(LP073HDUC) UYC093ALEU1(LP093CDUC) Y4NZ09ANLD1 (LP093HDUC1) UYC09EALE31(LP096CD3B) UYH09EALE31(LP096HD3B) UYC123ALEU1(LP123CDUC) Y4NZ12ANLD1 (LP123HDUC1) UYC12EALE31(LP126CD3B) UYH12EALE31(LP126HD3B) UYC153ALEU1(LP153CDUC) UYH153ALEU1(LP153HDUC) PTAC General information...
  • Page 15: List Of Functions

    6RWU0-05B List of functions 4. List of functions PTAC Type PTAC Type Category Function Cooling only Models Heat Pump Models Air discharge type Top discharge Top discharge Airflow direction control (up & down) Manual Manual Airflow direction control (left & right) Air flow Auto swing Airflow steps (fan/cool/heat)
  • Page 16: Features

    Features 6RWU0-05B 5. Features The following features can be found in PTAC (Packaged Terminal Air-Conditioners) :- n 2 -Way Air Flow Direction n Indoor Fan Speed Setting n Washable Filters n Two Fan Motors n Low Noise at High Air Volume n LED Diagnostics and Self Diagnostics n High Efficiency Compressor n Indoor Room Freeze Protection...
  • Page 17 Low Noise at High Air Volume New Blowers and Fans which are bigger and stronger than earlier ones operate at low rpm’s and have higher efficiency. High Efficiency Compressor LG Rotary compressors have low noise, low vibration and higher efficiency and reliability. Energy save mode This feature employs a programmable logic which enables the unit to minimize power consumption.
  • Page 18 Features 6RWU0-05B Electric Heater Electric heaters are used in cold regions when instant heating is required in the room. In such cases, electric heaters are preferred over heat pump models which sometimes require long times to achieve the desired heating effect. Electric Heater are of two types –...
  • Page 19 This feature extends the overall life of the compressor by preventing the short cycling of the air-conditioner. When the com- pressor restarts, LG PTAC is designed to give it a minimum of three minutes to have a time of equalizing the refrigerant pressures for optimizing the cycle.
  • Page 20 Formation of ice reduces the airflow through the coil and hence the efficiency of the air conditioning unit. The LG PTHP employs an active reverse cycle defrost function to melt the ice off the outdoor coil for ensuring room comfort conditions and savings from extended operation.
  • Page 21 6RWU0-05B Part 2 Product data 1 YA chassis ...................22 1.1 Features ......................22 1.2 List of functions ....................23 1.3 Specifications ....................24 1.4 Dimensions.......................30 1.5 Piping diagrams....................31 1.6 Wiring diagrams....................33 1.7 Capacity tables ....................35 1.8 Electrical characteristics ..................43 1.9 Operation range....................44 1.10 Sound level test method...................44 2 Control Devices..................45 2.1 Electronic Controls ...................45 PTAC...
  • Page 22: Ya Chassis

    6RWU0-05B YA Chassis 1. YA Chassis Models : UYC073ALEU1(LP073CDUC) UYC093ALEU1(LP093CDUC) UYC123ALEU1(LP123CDUC) UYC153ALEU1(LP153CDUC) UYH073ALEU1(LP073HDUC) Y4NZ09ANLD1(LP093HDUC1) Y4NZ12ANLD1(LP123HDUC1) UYH153ALEU1(LP153HDUC) UYC09EALE31(LP096CD3B) UYC12EALE31(LP126CD3B) UYH09EALE31(LP096HD3B) UYH12EALE31(LP126HD3B) 1.1 Features 2 -Way Air Flow Direction Indoor Fan Speed Setting Washable Filters Two Fan Motors Low Noise at High Air Volume LED Diagnostics and Self Diagnostics High Efficiency Compressor Indoor Room Freeze Protection...
  • Page 23: List Of Functions

    YA Chassis 6RWU0-05B 1.2 List of functions PTAC PTAC Category Function Cooling only Models Heat Pump Models Air flow Air discharge type Top discharge Top discharge Airflow direction control (up & down) Manual Manual Airflow direction control (left & right) Auto swing Airflow steps (fan/cool/heat) 2/2/2...
  • Page 24: Specifications

    6RWU0-05B YA Chassis 1.3 Specifications 208-230V COOLING ONLY MODELS Buyer Models LP073CDUC LP093CDUC LG Models UYC073ALEU1 UYC093ALEU1 2.08 2.14 2.73 2.78 Cooling Capacity Btu/h. 7,100 7,300 9,300 9,500 Heating Capacity ( for Heat Pump models) Btu/h. 2.3/3.2/4.6 2.4/3.3/4.7 2.3/3.2/4.6 2.4/3.3/4.7 Electric Heater capacity Btu/h.
  • Page 25 YA Chassis 6RWU0-05B Buyer Models LP123CDUC LP153CDUC LG Models UYC123ALEU1 UYC153ALEU1 3.52 3.58 4.37 4.43 Cooling Capacity Btu/h. 12,000 12,200 14,900 15,100 Heating Capacity ( for Heat Pump models) Btu/h. 2.3/3.2/4.6 2.4/3.3/4.7 2.3/3.2/4.6 2.4/3.3/4.7 Electric Heater capacity Btu/h. 7,800/10,900/15,700 8,100/11,200/16,000...
  • Page 26 6RWU0-05B YA Chassis 208-230V HEAT PUMP MODELS Buyer Models LP073HDUC LP093HDUC1 LG Models UYH073ALEU1 Y4NZ09ANLD1 2.08 2.14 2.93 2.99 Cooling Capacity Btu/h. 7,100 7,300 10,000 10,200 1.82 1.88 2.52 2.58 Heating Capacity ( for Heat Pump models) Btu/h. 6,200 6,400...
  • Page 27 YA Chassis 6RWU0-05B Buyer Models LP123HDUC1 LP153HDUC LG Models Y4NZ12ANLD1 UYH153ALEU1 3.49 3.55 4.37 4.43 Cooling Capacity Btu/h. 11,900 12,100 14,900 15,100 3.02 3.08 3.87 3.93 Heating Capacity ( for Heat Pump models) Btu/h. 10,300 10,500 13,200 13,400 2.3/3.2/4.6 2.4/3.3/4.7 2.3/3.2/4.6...
  • Page 28 6RWU0-05B YA Chassis 265V COOLING ONLY MODELS Buyer Models LP096CD3B LP126CD3B LG Models UYC09EALE31 UYC12EALE31 2.84 3.58 Cooling Capacity Btu/h. 9,700 12,200 Heating Capacity ( for Heat Pump models) Btu/h. Electric Heater capacity Btu/h. 12,600 12,600 Power Input Cooling/Heating 1,025...
  • Page 29 YA Chassis 6RWU0-05B 265V HEAT PUMP MODELS Buyer Models LP096HD3B LP126HD3B LG Models UYH09EALE31 UYH12EALE31 2.84 3.58 Cooling Capacity Btu/h. 9,700 12,200 2.49 3.22 Heating Capacity ( for Heat Pump models) Btu/h. 8,500 11,000 Electric Heater capacity Btu/h. 12,600 12,600...
  • Page 30: Dimensions

    6RWU0-05B YA Chassis 1.4 Dimensions Product Data PTAC...
  • Page 31: Piping Diagrams

    YA Chassis 6RWU0-05B 1.5 Piping diagrams Models : UYC073ALEU1(LP073CDUC) UYC09EALE31(LP096CD3B) UYC093ALEU1(LP093CDUC) UYC12EALE31(LP126CD3B) UYC123ALEU1(LP123CDUC) UYC153ALEU1(LP153CDUC) Liquid side Capillary Tube Heat Heat C.F.F Exchanger Exchanger (Condenser) (Evaporator) Axial Fan High Pressure S/W Compressor Gas side : 41.8/32.6(kgf/cm [595/463(lbf/in LOC. Description PCB Connector Thermistor for indoor Air temperature CN-IDAT2 Thermistor for evaporator temperature...
  • Page 32 6RWU0-05B YA Chassis Models : UYH073ALEU1(LP073HDUC) UYH09EALE31(LP096HD3B) Y4NZ09ANLD1(LP093HDUC1) UYH12EALE31(LP126HD3B) Y4NZ12ANLD1(LP123HDUC1) UYH153ALEU1(LP153HDUC) CAPILLARY TUBE (HEAT) CAPILLARY TUBE (COOL) CHECK VALVE HEAT HEAT EXCHANGER C.F.F EXCHANGER (EVAPORATOR) (CONDENSER) Axial Fan REVERSING VALVE ACCUMULATOR High Pressure S/W : 41.8/32.6(kgf/cm [595/463 (lbf/in Compressor Cooling Heating LOC.
  • Page 33: Wiring Diagrams

    YA Chassis 6RWU0-05B 1.6 Wiring diagrams Models : UYC09EALE31(LP096CD3B) UYH09EALE31(LP096HD3B) UYC12EALE31(LP126CD3B) UYH12EALE31(LP126HD3B) POWER INPUT NEUTRAL LIVE GN/YL INDOOR AIR THERMISTOR INDOOR COIL THERMISTOR OUTDOOR AIR THERMISTOR OUTDOOR COIL THERMISTOR CN-THERMO-S CN-AUX-S CN-ODT CN-IDPT CN-IDAT2 Pressure Switch HERM MAIN PWB.ASM INDOOR COMP MOTOR WCN-NOISE...
  • Page 34 6RWU0-05B YA Chassis CN-AUX-S CN-IDPT CN-THERMO-S CN-ODT CN-IDAT2 CN-DISP1 CN-DISP2 CN-WRITE CN-PRESS CN-DIP CN-4WAY CN-ICR CN-MOTOR_IDF CN-EXT(L) CN-MOTOR_ODF CN-EXT(N) CN-N Product Data PTAC PTAC...
  • Page 35: Capacity Tables

    YA Chassis 6RWU0-05B 1.7 Capacity tables Cooling Capacity UYC073ALEU1(LP073CDUC) Indoor Air Outdoor Air Temperature : DB°F Temperature 89.6 WB°F DB°F 57.2 68.0 5.92 5.80 0.36 5.80 5.88 0.43 5.52 6.00 0.50 60.8 71.6 6.91 5.65 0.37 6.76 5.71 0.44 6.44 5.82 0.51 64.4...
  • Page 36 6RWU0-05B YA Chassis UYC123ALEU1(LP123CDUC) Indoor Air Outdoor Air Temperature : DB°F Temperature 89.6 WB°F DB°F 57.2 68.0 9.89 9.38 0.67 9.69 9.49 0.80 9.23 9.69 0.93 60.8 71.6 11.55 9.13 0.68 11.30 9.23 0.81 10.77 9.40 0.94 64.4 77.0 12.88 8.89 0.69 12.61...
  • Page 37 YA Chassis 6RWU0-05B UYH073ALEU1(LP073HDUC) Indoor Air Outdoor Air Temperature : DB°F Temperature 89.6 WB°F DB°F 57.2 68.0 5.92 5.91 0.36 5.80 5.98 0.43 5.52 6.11 0.50 60.8 71.6 6.91 5.75 0.37 6.76 5.82 0.44 6.44 5.92 0.51 64.4 77.0 7.71 5.60 0.37 7.55...
  • Page 38 6RWU0-05B YA Chassis Y4NZ12ANLD1(LP123HDUC1) Indoor Air Outdoor Air Temperature : DB°F Temperature 89.6 WB°F DB°F 57.2 68.0 9.81 9.62 0.67 9.61 9.74 0.79 9.15 9.94 0.92 60.8 71.6 11.45 9.36 0.68 11.21 9.47 0.80 10.68 9.65 0.94 64.4 77.0 12.78 9.13 0.69 12.51...
  • Page 39 YA Chassis 6RWU0-05B UYC09EALE31(LP096CD3B) Indoor Air Outdoor Air Temperature : DB°F Temperature 89.6 WB°F DB°F 57.2 68.0 7.87 7.52 0.49 7.70 7.61 0.59 7.34 7.77 0.68 60.8 71.6 9.18 7.32 0.50 8.99 7.40 0.60 8.56 7.54 0.69 64.4 77.0 10.24 7.13 0.51 10.03...
  • Page 40 6RWU0-05B YA Chassis UYH09EALE31(LP096HD3B) Indoor Air Outdoor Air Temperature : DB°F Temperature 89.6 WB°F DB°F 57.2 68.0 7.87 7.52 0.49 7.70 7.61 0.59 7.34 7.77 0.68 60.8 71.6 9.18 7.32 0.50 8.99 7.40 0.60 8.56 7.54 0.69 64.4 77.0 10.24 7.13 0.51 10.03...
  • Page 41 YA Chassis 6RWU0-05B Heating Capacity UYH073ALEU1(LP073HDUC) Outdoor Air Temperature : DB°F Indoor Air Temperature 42.8 DB°F 60.8 5.89 0.45 6.85 0.49 7.42 0.51 8.19 0.55 64.4 5.71 0.47 6.64 0.50 7.18 0.53 7.93 0.57 68.0 5.54 0.48 6.40 0.52 6.97 0.55 7.69 0.59...
  • Page 42 6RWU0-05B YA Chassis UYH153ALEU1(LP153HDUC) Outdoor Air Temperature : DB°F Indoor Air Temperature 42.8 DB°F 60.8 12.34 1.10 14.35 1.19 15.53 1.25 17.14 1.34 64.4 11.95 1.14 13.89 1.23 15.04 1.29 16.60 1.38 68.0 11.59 1.17 13.40 1.27 14.59 1.33 16.10 1.43 71.6 11.17...
  • Page 43: Electrical Characteristics

    YA Chassis 6RWU0-05B 1.8 Electrical characteristics Unit Power Compressor Moter FLA Model Voltage Voltage range UYC073ALEU1(LP073CDUC) 16.0 UYC093ALEU1(LP093CDUC) 19.0 (208 V) UYC123ALEU1(LP123CDUC) 27.0 14.5/19.8/28.3 Min:187 UYC153ALEU1(LP153CDUC) 6.55 38.6 208~230 15/20/30 UYH073ALEU1(LP073HDUC) Max:253 16.0 (230 V) Y4NZ09ANLD1(LP093HDUC1) 26.0 13.6/18.6/26.2 0.36 0.36 Y4NZ12ANLD1(LP123HDUC1) 27.0 UYH153ALEU1(LP153HDUC)
  • Page 44: Operation Range

    6RWU0-05B YA Chassis 1.9 Operation range Cooling Heating (115°F) (75°F) Continuous Continuous operation operation (34°F) (70°F) Electric Heater Operative (54°F) (-4°F) 12(54°F) 30(86°F) 12(54°F) 30(86°F) Indoor Unit [℃ (℉) DB] Indoor Unit [℃ (℉) DB] 1.10 Sound level test method OutDoor Middle Wall InDoor...
  • Page 45: Control Devices

    Control Device 6RWU0-05B 2. Control Device 2.1 Electronic Controls The Electronic Controls and the panel display is as shown below. FAN SPEED • Every time you push this button, it cycles through the settings as follows: {High(F2)) → Low(F1)) → High(F2)} HEAT HIGH F1 LOW...
  • Page 46 6RWU0-05B Control Device • REMOVING THE FRONT GRILLE Additional controls are available after removing the front grille and option cover of control box. To remove the front grille, pull out the bottom of front grille and then lift up. To reinstall the front grille, place the tabs over the top of the unit and push the bottom of front grille until the clips snap into place.
  • Page 47 Control Device 6RWU0-05B • Remote/Local Control When remote/local switch #1 is on, it allows the unit to operate by the Remote Wall Thermostat. The unit control by knobs are not applicable. • Energy Saver When the energy saver switch #2 is on, it allows the fan to provide continuous operation in cool or heat modes. When the switch is off, it allows continuous circulation of room air to provide a balanced temperature in the room.
  • Page 48 6RWU0-05B Control Device Remote Wall Thermostat When the wires are connected, the unit will be controlled by a remote wall thermostat. The thermostat connections supply the 24 Volt AC. When you install the digital/electronic thermostat, you must set it to 24 Volt AC.
  • Page 49 Control Device 6RWU0-05B • Electrical Controls Fault Description of t n i Codes Inspection • Check the error after change sensor. Indoor Air The Indoor Air Thermistor Error occurs when • Check the insertion of PCB Connector CH 01 Thermistor Error the indoor temperature is ≤-35°C or ≥100°C.
  • Page 50 Part 3 Design and Installation 1 General installation procedure ............51 2 Installation of unit ................52 2.1 Safety precautions....................52 2.2 Points for explanation about operations ............52 2.3 Selecting installation site for the unit ..............52 2.4 Installation of Unit .....................56 2.5 Wall sleeve installation ..................58 Design and installation PTAC...
  • Page 51: General Installation Procedure

    General Installation Procedure 6RWU0-05B 1. General Installation Procedure Installation Procedure Remarks …… Check and confirm required load calculation, model Determination of work scope selection etc… …… The base or the foundation of the Air-Conditioner Selection of suitable location should be firm and vibration proof and air-flow should for unit not be restricted on either side of the unit - front and the back.
  • Page 52: Installation Of Unit

    6RWU0-05B Installation of unit 2. Installation of unit 2.1 Safety precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. n Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness is classified by the following indications.
  • Page 53 Installation of unit 6RWU0-05B WARNING Do not use a damaged power cord, plug or loose socket. • Otherwise there is risk of fire or electric shock. Always plug onto a grounded outlet. • Otherwise there is risk of fire or electric shock. Do not extend or modify the power cord length.
  • Page 54 6RWU0-05B Installation of unit Turn off the main power switch when the unit is not used for a long time. • We can prevent accidental startup and thereby prevent injury. Do not operate or stop the unit by inserting or pulling out the power plug. •...
  • Page 55: Selecting Installation Site For The Unit

    Installation of unit 6RWU0-05B CAUTION Install the product in such a way that the noise or hot wind from the outdoor unit may not cause any distur- bance to neighbors. • Otherwise there may be disputes with neighbors. During installation the unit should be level front-to-back and side-to-side. •...
  • Page 56: Installation Of Unit

    6RWU0-05A Installation of unit 2.4 Installation of unit The PTAC and its components are as shown below. 14 14 1. WALL SLEEVE 6. VERTICAL AIR DEFLECTOR 11. BASE PAN 2. FRONT GRILLE (HORIZONTAL LOUVER) 12. BRACE 3. AIR FILTER 7. EVAPORATOR 13.
  • Page 57 Wall opening 16-1/4"x42-1/4" Recommended To maintain the best performance of LG PTAC 1. An insulation strip must be attached. The insulation strip is provided with the box. 2. After assembly of unit with sleeve and front grille, the gap should be over 20” from both sleeve and front grille.
  • Page 58: Wall Sleeve Installation

    6RWU0-05B Installation of unit 2.5 WALL SLEEVE INSTALLATION Wall Case Installation Data framing, moving electrical outlets, and other expensive modifications. General Generally, units are installed 3" to 5" above the floor For existing construction it is important that carpentry, (flush to finished floor installation is possible) as near to masonry and electrical work be performed by compe- the center of the room as possible;...
  • Page 59 Construction room resulting in increased operating costs and improper As shipped, the LG wall sleeve is ready for installation. room temperature control. Do not remove the stiffener from inside the wall case or the...
  • Page 60 6RWU0-05B Installation of unit Installation PTAC...
  • Page 61 Installation of unit 6RWU0-05B PTAC Installation...
  • Page 62 6RWU0-05B Installation of unit • Unit Installation 2. Remove the front grille by pulling it out at the bottom 1. Remove the shipping screw from the ventilation door. to release it, then lift it up along the unit top front. 3.
  • Page 63 Installation of unit 6RWU0-05B ELECTRICAL SAFETY IMPORTANT (PLEASE READ CAREFULLY) FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three-prong (grounding) plug. PREFERRED Use this with a standard three-slot (grounding) wall power outlet to minimize the METHOD hazard of electric shock.
  • Page 64 Part 4 Accessories 1 Controller accessories ...............65 1.1 Hard Wire Kit ....................65 1.2 Wired Wall Thermostat Connection Kit.............67 2 Mechanical accessories ..............68 2.1 Control Panel Key Lock ..................68 2.2 Outer Grille .......................69 2.3 Condensate Drain Kit ..................71 2.4 Leveling Legs ....................73 2.5 Sub Base ......................74 2.6 Lateral Duct Accessory System ...............76 2.7 Replacement Filter - 10 Pack ................79...
  • Page 65: Controller Accessories

    Controller accessories 6RWU0-05B 1. Controller accessories 1.1 Hard Wire Kit (265 V ONLY) The Hard Wire kit consists of a Junction box which provides a protective enclosure for the electrical connections. This junc- tion box is furnished with approximately 2 - feet of inch flexible steel conduit and a metal box that secures to the...
  • Page 66 6RWU0-05B Controller accessories 5) For 265 volt units, remove and discard the red lead from the wire assembly. * For 208/230 volt units and 265 volt units refer to notes given below. 6) Remove the retaining ring, which holds the threaded conduit and the metal box together, from the straight conduit clamp. Insert the three wires into the metal box through one of the two openings in the box.
  • Page 67: Wired Wall Thermostat Connection Kit

    Mechanical accessories 6RWU0-05B 1.2 Wired Wall Thermostat Connection Kit Installation 1. Disconnect power and remove the front panel per unit The PTAC Wire Harness kit provides connection from termi- installation instruction. nal strip on the PTAC control board to the following board features: 2.
  • Page 68: Mechanical Accessories

    6RWU0-05B Mechanical accessories 2. Mechanical Accessories 2.1 Control Panel Key Lock Door Hinge Pins (Each Side) Brackets (Each Side) Control Panel Key Lock Front AYCP101 The Control Panel Key Lock Kit prevents tampering with the controls used to set the temperature and other Heating and Cooling functions.
  • Page 69: Outer Grille

    Mechanical accessories 6RWU0-05B 2.2 Outer Grille Outdoor Grilles are attached to the Wall Sleeve and exposed to the exterior Wall. These Grilles comes in industry standard size of 42" x 16". These Grilles are of two types : (a) Stamped Aluminum Grille Stamped Aluminum Grille AYRGALA01 and (b) Architecture Grille.
  • Page 70 The architectural design of a building may dictate the use of special or oversized louvers for aesthetic reasons. Louvers other than standard LG exterior grilles may be used on the LG unit, however, these special louvers, or any special exterior architectural treatments of the building facade that may restrict the free circulation of condenser airflow, should be referred to LG Engineering for evaluation and approval.
  • Page 71: Condensate Drain Kit

    Mechanical accessories 6RWU0-05B 2.3 Condensate Drain Kit. During the Heat Pump operation, condensate water inside the unit drains out into the sleeve from the chassis. Such an instance may also happen at times of high humidity during the cooling operation. When normal drainage from the wall sleeve is not possible or is undesirable, this condensate drain kit can be used.
  • Page 72 6RWU0-05B Mechanical accessories 3) Locate the other gasket A on the back of the bank off plate and secure the assembly to the left rear of the wall sleeve with sheet metal screws provided.(refer to figure on the right) If the unit is to be installed right away, install the condenser grille to the wall sleeve with the hardware provided.
  • Page 73 Mechanical accessories 6RWU0-05B 1) The components D, E and the drain fitting of the kit are mount- ed on the bottom of the wall sleeve prior to the installation of the sleeve. When a subbase is not used, a suitable area on the bottom of the sleeve is selected which is inside the room.
  • Page 74: Leveling Legs

    6RWU0-05B Mechanical accessories 2.4 Leveling legs IMPORTANT: Installer is responsible for com- Leveling Leg Accessory Kits include two leveling legs as plying with all building and well as two mounting screws. National Electrical Codes. They are constructed of formed sheet metal and are engineered to provide accurate leveling and support for PTAC units which do not utilize the optional subbase.
  • Page 75: Subbase

    Mechanical accessories 6RWU0-05B 2.5 Subbase The Subbase provides an enclosure for an electrical receptacle, power switch and a circuit breaker. Electrical connections to the power supply from the unit are made inside the subbase. In addition, the subbase provides structural support to the Wall Sleeve and to the weight of the PTAC unit .
  • Page 76 6RWU0-05B Mechanical accessories Installation Procedure: Inside Wall 1. Disconnect all power to unit. 2. Mark the hole location on sleeve then drill 1/8in holes. See Fig. 2 for hole dimensions on sleeve. 3. (Optional) Adjustable side extension panels can be SIDE VIEW OF WALL SLEEVE attached to cover open space left between subbase and 1/8”...
  • Page 77: Lateral Duct Accessory System

    Mechanical accessories 6RWU0-05B 2.6 Lateral Duct Accessory System The lateral duct accessory system allows one unit to heat or cool two rooms and can be installed for left or right side duct application. Pre-Installation Things to take into consideration before installation Front Grille •...
  • Page 78 6RWU0-05B Mechanical accessories Install the Extension Duct 1/8” 1. Temporarily secure plenum to left and right support brackets that were previously installed. WALL 1/8” 2. Measure and cut a 3 3/4 in. X 7 1/8 in. hole through adja- cent wall(fig.2) 3 3/4”...
  • Page 79: Replacement Filter - 10 Pack

    Mechanical accessories 6RWU0-05B 2.7 Replacement Filter ( 10 Pack ) The unit is provided with two easy-to-use replaceable mesh filters which can be cleaned periodically from time to time. Replacement Filter 10-Pack AYFT110 2.8 Wall Sleeve This Wall Sleeve comes in industry standard size of 42"...
  • Page 80: Remote Escutcheon Kit - 10 Pack

    6RWU0-05B Mechanical accessories 2.10 Remote Escutcheon Kit 3. Lift the cabinet front off the chassis. This kit provides an attractive replacement escutcheon, 4. Lift the front edge of the escutcheon as shown in figure 4. (see Figure 1). The kit allows the removal of control pads and graphics, which are not required when a wall thermo- stat is used to control the unit.
  • Page 81: Vent Filter

    Mechanical accessories 6RWU0-05B 2.11 Vent Filter The Vent filter is used to filter the air flowing inside the room when Air Ventilation is performed by means of the ventilation lever. Installation Procedure: The Installation and servicing of the equipment should be performed by qualified and experienced personnel only.
  • Page 82: Power Cord Accessories

    6RWU0-05B Power cord accessories 3.1Power cord FOR 230/208 VOLT POWER CORD CONNECTIONS ONLY 1. Remove the front gille by pulling it out at the 2. Remove cover by removing 3 screws from front. bottom to release it, then lift it up along the unit top front.
  • Page 83 B: Cooling + Corrosion Protection J: Heat Pump + Corrosion Protection C: Cooling + Condensate Pump K: Heat Pump + Condensate Pump E: Electronic Look. L: LG Chassis : A – YA chassis. Power Rating: 1: 115V, 60Hz 6: 220-240V, 50Hz E: 265V, 60Hz...
  • Page 84 Tianjin City, 300-402, China. http://www.lgeaircon.com All rights reserved The air conditioners manufactured by LG have received ISO9001 certificate for Printed in Korea August/2017 quality assurance and ISO14001 certificate for environmental management system. The specifications, designs, and information in this brochure are subject to...

Table of Contents