LG 6CIM0-01B Engineering Product Data Book
LG 6CIM0-01B Engineering Product Data Book

LG 6CIM0-01B Engineering Product Data Book

Indoor unit r410a 6cim0-01b (replaces 6cim0-01a)

Advertisement

Indoor unit

R410A
6CIM0-01B (Replaces 6CIM0-01A)

Advertisement

Table of Contents
loading

Summary of Contents for LG 6CIM0-01B

  • Page 1: Indoor Unit

    Indoor unit R410A 6CIM0-01B (Replaces 6CIM0-01A)
  • Page 2 Also energy efficiency, low noise and low maintenance are the features which are essential for these systems. As a part of vertical integration LG makes all the key components in house, which gives us an edge to LG to make better and latest technology products with best quality in optimized time.
  • Page 3: General Information

    Indoor unit General information 1. Model line up 2. Nomenclature 3. Appearance...
  • Page 4: Model Line Up

    Indoor unit 1. Model line up Model names Capacity, kW(kBtu/h Class) Category Chassis 2.64 3.52 5.28 (12) (18) AMNW09GDBL0 AMNW12GDBL0 [LMN096HVT] [LMN126HVT] Wall mounted AMNW18GDCL0 [LMN186HVT] AMNW09GDBR0 AMNW12GDBR0 [LMAN096HVT] [LMAN126HVT] ARTCOOL Mirror AMNW18GDCR0 [LMAN186HVT] AMNW12GTRA0 [LMCN125HV] Ceiling cassette AMNW18GTQA0 [LMCN185HV] AMNW09GB1A0 AMNW12GB1A0 [LMDN095HV]...
  • Page 5: Wall Mounted

    Indoor unit 2. Nomenclature 2.1 Global model names Serial number Function A : Basic, L : Plasma (Wall mounted) C : Plasma(ceiling cassette) ART COOL(Mirror) type front panel color R : Mirror Chassis name Indoor unit type D : Wall Mounted, ART COOL Mirror T : Ceiling cassette, B : Ceiling concealed duct Electrical rating G: 208/230V, 1Ø, 60Hz...
  • Page 6: Indoor Units

    Indoor unit 3. Appearance 3.1 Indoor units • Wall Mounted • ART COOL Mirror AMNW09GDBR0 [LMAN096HVT] AMNW09GDBL0 [LMN096HVT] AMNW12GDBR0 [LMAN126HVT] AMNW12GDBL0 [LMN126HVT] AMNW18GDCR0 [LMAN186HVT] AMNW18GDCL0 [LMN186HVT] • Ceiling Concealed Duct – Low static pressure • Ceiling Cassette 4-way AMNW09GB1A0 [LMDN095HV] AMNW12GTRA0 [LMCN125HV] AMNW18GTQA0 [LMCN185HV] AMNW12GB1A0 [LMDN125HV]...
  • Page 7 Indoor unit 1. Wall Mounted 2. ART COOL Mirror 3. Ceiling cassette 4-way 4. Ceiling concealed duct - Low static pressure...
  • Page 8 Indoor unit Wall Mounted 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. Air flow and temperature distributions (reference data) 8. Sound levels 9. Controller 10. Installation...
  • Page 9: List Of Functions

    Indoor unit 1. List of functions AMNW09GDBL0 [LMN096HVT] Category Functions AMNW12GDBL0 [LMN126HVT] AMNW18GDCL0 [LMN186HVT] Air supply outlet Airflow direction control (left & right) Auto Airflow direction control (up & down) Auto Auto swing (left & right) Air flow Auto swing (up & down) Airflow steps (fan/cool/heat) 5 / 6 / 6 Chaos wind(auto wind)
  • Page 10: Specifications

    Indoor unit 2. Specifications AMNW09GDBL0 AMNW12GDBL0 AMNW18GDCL0 Model Name [LMN096HVT] [LMN126HVT] [LMN186HVT] Power Supply V, Ø, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 Nominal kW Class Capacity Nominal Btu/h Class 9,000 12,000 18,000 Casing Color White White White W x H x D 895 ×...
  • Page 11 Indoor unit 3. Dimensions Wall mounted...
  • Page 12 Indoor unit 3. Dimensions Wall mounted...
  • Page 13: Amnw09Gdbl0 [Lmn096Hvt

    Indoor unit 4. Piping diagrams Gas pipe connection port Heat Exchanger (flare connection) Thermistor for Evaporator Cross Flow Fan Outlet Temperature Liquid pipe connection port (flare connection) n Refrigerant pipe connection port diameters Unit : mm(inch) Model Liquid AMNW09GDBL0 [LMN096HVT] Ø9.52(3/8) Ø6.35(1/4) AMNW12GDBL0 [LMN126HVT]...
  • Page 14: Amnw12Gdbl0[Lmn126Hvt]

    Indoor unit 5. Wiring diagrams Models : AMNW09GDBL0 [LMN096HVT] / AMNW12GDBL0 [LMN126HVT] Models : AMNW18GDCL0 [LMN186HVT] Wall mounted...
  • Page 15: Capacity Tables

    Indoor unit 6. Capacity Tables n Cooling Capacity Cooling Capacity Indoor Air Temp. °F DB/ °F WB Outdoor Unit Size air temp. 68.0 / 57.2 71.6 / 60.8 77.0 / 64.4 80.6 / 66.2 86.0 / 71.6 89.6 / 75.2 (kBtu/h(kW)) °F DB 68.0...
  • Page 16: Heating Capacity

    Indoor unit 6. Capacity Tables n Heating Capacity Heating capacity Outdoor Air Temp. °F WB Indoor air Unit Size temp. (kBtu/h(kW)) °F DB 60.8 10.5 10.9 11.0 64.4 10.4 10.9 10.9 68.0 10.4 10.9 10.9 (2.64) 70.0 10.4 10.8 10.8 71.6 10.3 10.7...
  • Page 17: Amnw09Gdbl0 [Lmn096Hvt

    Indoor unit 7. Air flow and temperature distributions (reference data) Model : AMNW09GDBL0 [LMN096HVT] Cooling Heating Discharge angle : 40° Discharge angle : 50° Air velocity [ft/s] Air velocity [ft/s] 16ft 13ft 10ft 16ft 13ft 10ft Temperature [°F] Temperature [°F] 16ft 13ft 10ft...
  • Page 18 Indoor unit 7. Air flow and temperature distributions (reference data) Model : AMNW18GDCL0 [LMN186HVT] Cooling Heating Discharge angle : 40° Discharge angle : 50° Air velocity [ft/s] Air velocity [ft/s] 26ft 23ft 20ft 16ft 13ft 10ft 26ft 23ft 20ft 16ft 13ft 10ft Temperature [°F]...
  • Page 19: Table Of Contents

    Indoor unit 8. Sound levels Overall Notes: - Sound measured at 3.3ft away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference accoustic pressure 0dB=20μPa. 3.3ft - Sound level will vary depending on a range of factors such as 2.6ft...
  • Page 20: Wireless Remote Control

    Indoor unit 9. Controller Wireless remote control Control Display Description panel screen Plasma button*:Plasmaster filter purifies the air by removing mites, micro dust and pet fur. Plasmaster Ionizer sterilize the aerial bacteria and other harmful substances. Display Sleep mode auto button*: Sets the sleep mode auto operation.
  • Page 21 Indoor unit 10. Installation • Please read the instruction sheets completely before installing the product. • When the power cord is damaged, replacement work shall be performed by authorized personnel only. • Installation work must be performed in accordance with the national wiring standards by authorized personal only. Installation plate Sleeve Bushing-Sleeve...
  • Page 22 Indoor unit 10. Installation 2) Installation plate dimensions Type 1: SB Chassis 14 _ Wall mounted...
  • Page 23 Indoor unit 10. Installation Type 2: SC Chassis CAUTION • Use only those accessories (Standard or optional) which have designated specilications _ 15 Wall mounted...
  • Page 24: Selection Of The Best Location

    Indoor unit 10. Installation ② Measure the wall and mark the centerline. It is also 10.2 Selection of the best location important to use caution concerning the location of the ① There should not be any heat or steam near the unit. installation plate.
  • Page 25: Connecting The Piping

    Indoor unit 10. Installation Wrong method 1) Installation of Indoor Unit • Following bending type from left to right may cause dam- ① Hook the indoor unit onto the upper portion of the instal- age to the tubing. lation plate.( engage the three hooks at the top of the indoor unit with the upper edge of the installation plate) Ensure that the hooks are properly seated on the instal- lation plate by moving it left and right...
  • Page 26 Indoor unit 10. Installation Wiring and Piping Connection <Right side piping> ① Insert the connecting cable through the bottom side of indoor unit and connect the cable (You can see detail contents in 'Connecting the cables' section) Tape Connecting cable Drain hose View Connecting pipe...
  • Page 27 Indoor unit 10. Installation 3) Wrap the insulation material around the 4) Finishing the indoor unit installation connecting portion. ① Mount the tubing holder in the original positon. ② Ensure that the hooks are properly seated on the instal- ① Overlap the connection pipe heat insulation and the lation plate by moving it left and right.
  • Page 28: Checking The Drainage

    Indoor unit 10. Installation 10.6 Checking the Drainage 2) Drain piping ① The drain hose should point downward for easy drain 1) To check the drainage. flow. ① Pour a glass of water on the evaporator. ② Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain Downward slope exit.
  • Page 29 Indoor unit ART COOL Mirror 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. Air flow and temperature distributions (reference data) 8. Sound levels 9. Controller 10. Installation...
  • Page 30 Indoor unit 1. List of functions AMNW09GDBR0 [LMAN096HVT] Category Functions AMNW12GDBR0 [LMAN126HVT] AMNW18GDCR0 [LMAN186HVT] Air supply outlet Airflow direction control (left & right) Auto Airflow direction control (up & down) Auto Auto swing (left & right) Air flow Auto swing (up & down) Airflow steps (fan/cool/heat) 5 / 6 / 6 Chaos wind(auto wind)
  • Page 31: Sound Pressure Level

    Indoor unit 2. Specifications AMNW09GDBR0 AMNW12GDBR0 AMNW18GDCR0 Model Name [LMAN096HVT] [LMAN126HVT] [LMAN186HVT] Power Supply V, Ø, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 Nominal kW Class Capacity Nominal Btu/h Class 9,000 12,000 18,000 Casing Color Grace Dark Gray Grace Dark Gray White W x H x D...
  • Page 32 Indoor unit 3. Dimensions ART COOL Mirror...
  • Page 33 Indoor unit 3. Dimensions ART COOL Mirror...
  • Page 34: Piping Diagrams

    Indoor unit 4. Piping diagrams Gas pipe connection port Heat Exchanger (flare connection) Thermistor for Evaporator Cross Flow Fan Outlet Temperature Liquid pipe connection port (flare connection) n Refrigerant pipe connection port diameters Unit : mm(inch) Model Liquid AMNW09GDBR0 [LMAN096HVT] Ø9.52(3/8) Ø6.35(1/4) AMNW12GDBR0 [LMAN126HVT...
  • Page 35: Wiring Diagrams

    Indoor unit 5. Wiring diagrams Models : AMNW09GDBR0 [LMAN096HVT] / AMNW12GDBR0 [LMAN126HVT] Models : AMNW18GDCR0 [LMAN186HVT] ART COOL Mirror...
  • Page 36 Indoor unit 6. Capacity Tables n Cooling Capacity Cooling Capacity Indoor Air Temp. °F DB/ °F WB Outdoor Unit Size air temp. 68.0 / 57.2 71.6 / 60.8 77.0 / 64.4 80.6 / 66.2 86.0 / 71.6 89.6 / 75.2 (kBtu/h(kW)) °F DB 68.0...
  • Page 37 Indoor unit 6. Capacity Tables n Heating Capacity Heating capacity Outdoor Air Temp. °F WB Indoor air Unit Size temp. (kBtu/h(kW)) °F DB 60.8 10.5 10.9 11.0 64.4 10.4 10.9 10.9 68.0 10.4 10.9 10.9 (2.64) 70.0 10.4 10.8 10.8 71.6 10.3 10.7...
  • Page 38 Indoor unit 7. Air flow and temperature distributions (reference data) Model : AMNW09GDBR0 [LMAN096HVT] Cooling Heating Discharge angle : 40° Discharge angle : 50° Air velocity [ft/s] Air velocity [ft/s] 16ft 13ft 10ft 16ft 13ft 10ft Temperature [F] Temperature [F] 16ft 13ft 10ft...
  • Page 39 Indoor unit 7. Air flow and temperature distributions (reference data) Model : AMNW18GDCR0 [LMAN186HVT] Cooling Heating Discharge angle : 40° Discharge angle : 50° Air velocity [ft/s] Air velocity [ft/s] 26ft 23ft 20ft 16ft 13ft 10ft 26ft 23ft 20ft 16ft 13ft 10ft Temperature [F]...
  • Page 40: Sound Levels

    Indoor unit 8. Sound levels Overall Notes: - Sound measured at 3.3ft away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. 3.3ft - Reference accoustic pressure 0dB=20Pa. - Sound level will vary depending on a range of factors such as 2.6ft the construction(acoustic absorption coefficient) of particular...
  • Page 41 Indoor unit 9. Controller Wireless remote control Control Display Description panel screen Plasma button*:Plasmaster filter purifies the air by removing mites, micro dust and pet fur. Plasmaster Ionizer sterilize the aerial bacteria and other harmful substances. Display screen Sleep mode auto button*: Sets the sleep mode auto operation.
  • Page 42 Indoor unit 10. Installation • Please read the instruction sheets completely before installing the product. • When the power cord is damaged, replacement work shall be performed by authorized personnel only. • Installation work must be performed in accordance with the national wiring standards by authorized personal only. Installation plate Sleeve Bushing-Sleeve...
  • Page 43 Indoor unit 10. Installation 2) Installation plate dimensions Type 1: SB Chassis 14 _ ART COOL Mirror...
  • Page 44 Indoor unit 10. Installation Type 2: SC Chassis CAUTION • Use only those accessories (Standard or optional) which have designated specilications _ 15 ART COOL Mirror...
  • Page 45 Indoor unit 10. Installation ② Measure the wall and mark the centerline. It is also 10.2 Selection of the best location important to use caution concerning the location of the ① There should not be any heat or steam near the unit. installation plate.
  • Page 46 Indoor unit 10. Installation Wrong method 1) Installation of Indoor Unit • Following bending type from left to right may cause dam- ① Hook the indoor unit onto the upper portion of the instal- age to the tubing. lation plate.( engage the three hooks at the top of the indoor unit with the upper edge of the installation plate) Ensure that the hooks are properly seated on the instal- lation plate by moving it left and right...
  • Page 47 Indoor unit 10. Installation <Right side piping> <Right side piping> Tape Connecting View pipe Drain hose Terminal block Remote controller cable Connecting cable 2) Connecting the installation pipe and Cable retainer drain hose to the indoor unit. ① Align the center of the pipes and sufficiently tighten the flare nut by hand ②...
  • Page 48 Indoor unit 10. Installation 3) Wrap the insulation material around the 4) Finishing the indoor unit installation connecting portion. ① Mount the tubing holder in the original positon. ② Ensure that the hooks are properly seated on the instal- ① Overlap the connection pipe heat insulation and the lation plate by moving it left and right.
  • Page 49 Indoor unit 10. Installation 10.6 Checking the Drainage 2) Drain piping ① The drain hose should point downward for easy drain 1) To check the drainage. flow. ① Pour a glass of water on the evaporator. ② Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain Downward slope exit.
  • Page 50 Indoor unit Ceiling cassette 4-way 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. Air flow and temperature distributions (reference data) 8. Sound levels 9. Controller 10. Installation...
  • Page 51 Indoor unit 1. List of functions AMNW12GTRA0 [LMCN125HV] Category Function AMNW18GTQA0 [LMCN185HV] Air supply outlet Airflow direction control (left & right) Airflow direction control (up & down) Auto Auto swing (left & right) Air flow Auto swing (up & down) Airflow steps (fan/cool/heat) 4 / 5 / 4 Chaos wind(auto wind)
  • Page 52 Indoor unit 2. Specifications AMNW12GTRA0 AMNW18GTQA0 Model Name [LMCN125HV] [LMCN185HV] Power Supply V, Ø, Hz 208/230, 1, 60 208/230, 1, 60 Nominal kW Class Capacity Nominal Btu/h Class 12,000 18,000 Casing Color W x H x D 570 × 214 × 570 570 ×...
  • Page 53 Indoor unit 3. Dimensions Ceiling cassette 4-way...
  • Page 54 Indoor unit 3. Dimensions Ceiling cassette 4-way...
  • Page 55 Indoor unit 4. Piping diagrams Gas pipe connection port Heat exchanger (flare connection) Thermistor for Evaporator Turbo fan Outlet Temperature Liquid pipe connection port (flare connection) n Refrigerant pipe connection port diameters Unit : mm(inch) Model Liquid AMNW12GTRA0[LMCN125HV] Ø9.52(3/8) Ø6.35(1/4) AMNW18GTQA0[LMCN185HV] Ø12.7(1/2) Ø6.35(1/4)
  • Page 56 Indoor unit 5. Wiring diagrams Models: AMNW12GTRA0[LMCN125HV] / AMNW18GTQA0[LMCN185HV] Ceiling cassette 4-way...
  • Page 57 Indoor unit 6. Capacity Tables n Cooling Capacity Cooling Capacity Indoor Air Temp. °F DB/ °F WB Outdoor Unit Size air temp. 68.0 / 57.2 71.6 / 60.8 77.0 / 64.4 80.6 / 66.2 86.0 / 71.6 89.6 / 75.2 (kBtu/h(kW)) °F DB 68.0...
  • Page 58 Indoor unit 6. Capacity Tables n Heating Capacity Heating capacity Outdoor Air Temp. °F WB Indoor air Unit Size temp. (kBtu/h(kW)) °F DB 60.8 11.3 12.6 14.0 14.6 14.6 64.4 11.2 12.5 13.9 14.5 14.5 68.0 11.2 12.5 13.9 14.5 14.5 (3.52) 70.0...
  • Page 59 Indoor unit 7. Air flow and temperature distributions (reference data) Model : AMNW12GTRA0[LMCN125HV] Cooling Heating Discharge angle: 40° Discharge angle: 50° Air velocity [ft/s] Air velocity [ft/s] Temperature [°F] Temperature [°F] Model : AMNW18GTQA0[LMCN185HV] Cooling Heating Discharge angle : 40° Discharge angle : 50°...
  • Page 60 Indoor unit 8. Sound levels Overall Notes: - Sound measured at 4.9ft away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. Ceiling - Reference accoustic pressure 0dB=20Pa. - Sound level will vary depending on a range of factors such as 4.9ft the construction(acoustic absorption coefficient) of particular...
  • Page 61: Operation Mode

    Indoor unit 9. Controller Wired remote controller(PQWRHDF0) PLASMA Button (Optional) Used to start or stop the plasma-purification function. JET COOL Button Speed cooling operates super high fan speed. OPERATION MODE SELECTION Button Used to select the operation mode. FUNCTION SETTING Button Used to set or clear Auto Clean or Smart Clean.
  • Page 62 Indoor unit 10. Installation • Please read the instruction sheets completely before installing the product. • When the power cord is damaged, replacement work shall be performed by authorized personnel only. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Anti-fungus Air Outlet Air Inlet...
  • Page 63: Indoor Unit Installation

    Indoor unit 10. Installation 10.2 Selection of the best location 10.3 Precautions regarding cassette indoor unit installation • There should not be any heat source or steam near the unit. • There should not be any obstacles to the air circulation. 1) Main points about the indoor installation •...
  • Page 64 Indoor unit 10. Installation - Countermeasure: • Refrigerant piping: Increase the piping insulation thickness with thickness above 13/16 inch. • Use the carpet on the floor (compared to the tiles the carpet over it will have a 3 degree rise in temperature) Refrigerant piping •...
  • Page 65 Indoor unit 10. Installation 10.4 Ceiling opening dimensions and 1) Install the suspension bolts. hanging bolt location (Use either a W3/8” or M10 size bolt) Use a hole-in anchor for existing ceilings, and a sunken insert, sunken anchor or ① The dimensions of the paper pattern for installation are other field supplied parts for new ceilings to reinforce the the same as those of the ceiling opening dimensions.
  • Page 66: Connecting Pipes To The Indoor Unit

    Indoor unit 10. Installation • The following parts are local purchasing. 10.6 Connecting pipes to the indoor unit - Hanging Bolt - W 3/8 or M10 1) Refrigerant piping work - Nut - W 3/8 or M10 please refer “REFRIGERANT PIPING WORK”. - Spring Washer - M10 2) Piping insulation - Plate Washer - M10...
  • Page 67: Installation Of Decoration Panel

    Indoor unit 10. Installation • Be sure to install heat insulation on the drain piping. 10.7 Installation of decoration panel Heat insulation material: Polyethylene foam with thick- CAUTION ness more than 13/32". • Properly install decoration panel because any slit or gab between unit and decoration panel will result cool air leakage which may responsible for water driblling.
  • Page 68 Indoor unit 10. Installation 3. Fit the panel on the unit by inserting hooks as 6. Open two screws of control panel cover. shown in picture. Hook clip Screw Hook 7. Connect one display connector and two vane control connectors of front panel to indoor unit PCB.
  • Page 69: Electric Wiring Work

    Indoor unit 10. Installation 10.8 Electric wiring work 12k/18kBtu/h Class (1Ø) Terminal block in indoor 1) General instructions 1(L1) 2(L2) ① All field supplied parts and materials, electric works must conform to local codes. Use copper wire only. Connected to outdoor Unit Air fresh kit (Option) ②...
  • Page 70 Indoor unit 10. Installation NOTE 1. Use round crimp-style terminals for connecting 3. Do not connect wires of different gauge to the same grounding terminal. Loose connection may wires to the power supply terminal block. If unavailable, observe the following points when deteriorate protection.
  • Page 71 Indoor unit Ceiling concealed duct - Low static pressure 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. External pressure setting 8. Sound levels 9. Controller 10. Installation...
  • Page 72 Indoor unit 1. List of functions AMNW09GB1A0 [LMDN095HV] AMNW12GB1A0 [LMDN125HV] Category Function AMNW18GB2A0 [LMDN185HV] Air supply outlet Airflow direction control (left & right) Airflow direction control (up & down) Auto swing (left & right) Air flow Auto swing (up & down) Airflow steps (fan/cool/heat) 3 / 3 / 3 Chaos wind(auto wind)
  • Page 73 Indoor unit 2. Specifications AMNW09GB1A0 AMNW12GB1A0 AMNW18GB2A0 Model Name [LMDN095HV] [LMDN125HV] [LMDN185HV] Power Supply V, Ø, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 Nominal kW Class Capacity Nominal Btu/h Class 9,000 12,000 18,000 Casing Color W x H x D 820 ×...
  • Page 74 Indoor unit 3. Dimensions Ceiling concealed duct - low static pressure...
  • Page 75 Indoor unit 3. Dimensions Ceiling concealed duct - low static pressure...
  • Page 76 Indoor unit 4. Piping diagrams Models: AMNW09GB1A0[LMDN095HV] / AMNW12GB1A0[LMDN125HV] Gas pipe connection port Heat exchanger (flare connection) Thermistor for Evaporator Sirocco Fan Outlet Temperature Liquid pipe connection port (flare connection) n Refrigerant pipe connection port diameters Unit : mm(inch) Model Liquid AMNW09GB1A0[LMDN095HV] ø9.52(3/8)
  • Page 77 Indoor unit 4. Piping diagrams Models: AMNW18GB2A0[LMDN185HV] Gas pipe connection port Heat exchanger (flare connection) Thermistor for Evaporator Sirocco Fan Outlet Temperature Liquid pipe connection port (flare connection) n Refrigerant pipe connection port diameters Unit : mm(inch) Model Liquid AMNW18GB2A0[LMDN185HV] ø12.7(1/2) ø6.35(1/4) Description...
  • Page 78 Indoor unit 5. Wiring diagrams Models: AMNW09GB1A0[LMDN095HV] / AMNW12GB1A0[LMDN125HV] AMNW18GB2A0[LMDN185HV] Ceiling concealed duct - low static pressure...
  • Page 79 Indoor unit 6. Capacity Tables Cooling Capacity Indoor Air Temp. °F DB/ °F WB Outdoor Unit Size air temp. 68.0 / 57.2 71.6 / 60.8 77.0 / 64.4 80.6 / 66.2 86.0 / 71.6 89.6 / 75.2 (kBtu/h(kW)) °F DB 68.0 77.0 89.6...
  • Page 80 Indoor unit 6. Capacity Tables Heating capacity Outdoor Air Temp. °F WB Indoor air Unit Size temp. (kBtu/h(kW)) °F DB 60.8 10.5 10.9 11.0 64.4 10.4 10.9 10.9 68.0 10.4 10.9 10.9 (2.64) 70.0 10.4 10.8 10.8 71.6 10.3 10.7 10.8 75.2 10.0...
  • Page 81 Indoor unit 7. External pressure setting E.S.P. Control provide required constant air flow rate irrespective of E.S.P. charge. CAUTION Installer setting mode is to set the detail function of the remote controller. If the installer setting mode is not set correctly, it can cause problems to the product, user injury or property damage. This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated person should be respon- sible for the results.
  • Page 82 Indoor unit 7. External pressure setting How to Set E.S.P. on the remote controller? This is the function that decides the strength of the wind for each wind level and because this function is to make the installation easier. • If you set ESP incorrectly, the air conditioner may malfunction. •...
  • Page 83 Indoor unit 7. External pressure setting E.S.P. setting value (reference) Static pressure(mmAq(in.Aq)) 0(0.0) 1(0.04) 2(0.08) 3(0.12) 4(0.16) Model name Step(Hi/Mid/Lo) Setting value 8.5 CMM(300CFM) AMNW09GB1A0 7.5 CMM(265CFM) [LMDN095HV] 6.5 CMM(230CFM) 9.5 CMM(336CFM) AMNW12GB1A0 8.5 CMM(300CFM) [LMDN125HV] 7.5 CMM(265CFM) 15 CMM(530CFM) AMNW18GB2A0 13.5 CMM(477CFM) [LMDN185HV]...
  • Page 84 Indoor unit 8. Sound levels Overall Notes: - Data is valid at nominal operation condition - Reference accoustic pressure OdB = 20Pa - Sound level will vary depending on a range of factors such as Ceiling the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.
  • Page 85 Indoor unit 9. Controller 1) Wired remote controller Model name : PQRCVCL0QW (White Color_Supplied) / PQRCVCL0Q (Black Color_Accessory) 1. Operation Display Panel 2. Temperature Control Button 3. Fan Speed Button 4. On/Off Button 5. Operation Mode select Button SPEED TEMP OPER MODE 14 _...
  • Page 86 Indoor unit 9. Controller 2) Wide wired remote controller(accessory) Model name : PQRCVSL0QW (White Color) / PQRCVSL0 (Black Color) Please attach the inform label inside of the door. Please choose proper language depend on your country. OPERATION INDICATION SCREEN FUNCTION SETTING Button SET TEMPERATURE Button VENTILATION Button FAN SPEED Button...
  • Page 87 Indoor unit 10. Installation • Please read the instruction sheets completely before installing the product. • When the power cord is damaged, replacement work shall be performed by authorized personnel only. • Installation work must be performed in accordance with the national wiring standards. Air outlet vents Air return Air filter...
  • Page 88: Ceiling Dimension And Hanging

    Indoor unit 10. Installation 10.2 Selection of the best location • B1/B2 Chassis Install the air conditioner in the location that satisfies the fol- lowing conditions. • The place shall easily bear a load exceeding four times the indoor unitʼs weight. •...
  • Page 89 Indoor unit 10. Installation • Low static duct type in case of suction from back side. 10.4 Position of suspension bolt Air Filter ① A place where the unit will be leveled and that can sup- port the weight of the unit. ②...
  • Page 90 Indoor unit 10. Installation ⑥ Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ceiling. ⑦ Mount the suspension bolts to the set anchor firmly. Liquid pipe ⑧ Secure the installation plates onto the suspension bolts Refrigerant pipe and thermal (adjust level roughly) using nuts, washers and spring insulation(Local supply)
  • Page 91 Indoor unit 10. Installation 3) Indoor unit drain piping • Lay the drain hose with a downware inclination so water will drain out. ① Drain piping must have down-slope (1/50 to 1/100): be sure not to provide up-and-down slope to prevent rever- Thermal insulator sal flow.
  • Page 92 Indoor unit 10. Installation ② Check the drainage - With drain pump ① Possible drain head height is upto 27 6/19 inch. So the • Spray one or two glasses of water on the evaporator. drain head should be below 27 6/19 inch. •...
  • Page 93 Indoor unit 10. Installation Clamping of cables NOTE ① Arrange 2 power cables on the control panel. ② First, fasten the steel clamp with a screw to the inner 1. Use round crimp-style terminals for connecting boss of control panel. wires to the power supply terminal block.
  • Page 94 Yeouido P.O.Box 335 Seoul, 150-721, Korea. http://www.lgeaircon.com All rights reserved The air conditioners manufactured by LG have received ISO9001 certificate for Printed in Korea December / 2012 quality assurance and ISO14001 certificate for environmental management system. The specifications, designs, and information in this brochure are subject to change without notice.