Agilent Technologies IDP-7 Instruction Manual

Agilent Technologies IDP-7 Instruction Manual

Dry scroll vacuum pump
Hide thumbs Also See for IDP-7:

Advertisement

Vacuum Products Division
IDP-7
INSTRUCTION MANUAL
Dry Scroll
Vacuum Pump
Manual No. X3807-90009
Revision A
January 2017

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies IDP-7

  • Page 1 Vacuum Products Division IDP-7 INSTRUCTION MANUAL Dry Scroll Vacuum Pump Manual No. X3807-90009 Revision A January 2017...
  • Page 2 IDP-7 Dry Scroll Vacuum Pump Slo-Blo and Littelfuse are registered trademarks of Littelfuse, Inc. Copyright 2017 Agilent, Inc.
  • Page 3: Warranty

    IDP-7 Dry Scroll Vacuum Pump Warranty Warranty Replacement Products manufactured by Seller are warranted against defects in materials and workmanship for twelve (12) and Adjustment months from date of shipment thereof to Customer, and Seller's liability under valid warranty claims is limited, at...
  • Page 4: Table Of Contents

    Avertissements CEM ..... . . 6 IDP-7 Power Cord Selection ... . 13 Avertissement Classe A EN 55011 .
  • Page 5: Instructions For Use

    The IDP-7 is a hermetic, dry scroll vacuum pump. This pump is suitable for pumping air or inert gases. The pump Total weight of the packing, IDP-7 pump included, is is not intended to pump corrosive, explosive, or particu- approximately 28.1 kg (62 lbs).
  • Page 6: Emc Warnings

    IDP-7 Dry Scroll Vacuum Pump EMC Warnings This device complies with Part 15 of the FCC rules. Oper- EN 55011 Class A Warning ation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this This is a Class A product.
  • Page 7: Installation

    IDP-7 Dry Scroll Vacuum Pump Installation Maintenance The IDP-7 is NOT intrinsically safe. Do not install or use Personnel responsible for pump operation and mainte- the pump in an environment exposed to atmospheric nance must be well-trained and aware of the accident agents (rain, snow, ice), dust, aggressive gases, or in prevention rules.
  • Page 8: Environmental Conditions, Compliance And Utility

    ❑ Changes or modifications not expressly approved by NOTE Pollution level describes the degree to Agilent Technologies could void the user's authority to which a solid, liquid, or gas which dete- operate the equipment. riorates dielectric strength is adhering. 2 applies to a normal indoor atmosphere.
  • Page 9: Instructions D'utilisation

    Si elle manifeste des signes de dommages, qui peu- vent s’être produits lors du transport, contactez votre L'IDP-7 est une pompe à vide à spirales à sec hermétique. bureau des ventes local. Cette pompe est adaptée au pompage de l'air ou des gaz inertes.
  • Page 10: Avertissements Cem

    IDP-7 Dry Scroll Vacuum Pump Avertissements CEM Cet appareil est conforme à la Partie 15 des règles de la Avertissement Classe A EN 55011 FCC. L'opération est sujette aux deux conditions suiva- ntes : (1) ce dispositif ne provoque pas d'interférence Il s'agit d'un produit de la Classe A.
  • Page 11: Installation

    IDP-7 Dry Scroll Vacuum Pump Installation Utilisation L'IDP-7 n'est PAS intrinsèquement sûre. Ne pas installer Afin d'atteindre le vide maximal, la pompe doit être ou utiliser la pompe dans un environnement exposé à des laissée en marche pendant au moins 24 heures avec le agents atmosphériques (pluie, neige, glace), à...
  • Page 12: Entretien

    IDP-7 Dry Scroll Vacuum Pump Entretien Mise au rebut Signification du logo WEEE figurant sur les étiquettes. Le personnel responsable de l'opération et de l'entretien Le symbole ci-dessous est appliqué conformément à la de la pompe doit être bien formé et conscient des règles directive CE nommée "WEEE".
  • Page 13: Technical Information

    IDP-7 Dry Scroll Vacuum Pump Technical Information Table 1 Specifications Model IDP-7 Dry Scroll Single Hermetic Vacuum Pump Dimensions 248 x 260 x 421 (h x w x l [mm]) Peak pumping speed 50 Hz: 120 L/m, 7.2 m 60 Hz: 152 L/min (9.1 m...
  • Page 14: Outline Drawing With Dimensions

    IDP-7 Dry Scroll Vacuum Pump Figure 1 Outline Drawing with Dimensions Figure 2 Pumping Speed Curves...
  • Page 15: Unpacking And Inspection

    Unpacking and Inspection 1. Orient the shipping container with “This End Up” on top. 2. Open the box and carefully lift the IDP-7 out of the box. 3. Save the carton and all packing materials. 4. Inspect the pump for damage. If there is shipping...
  • Page 16: Installation

    IDP-7 Dry Scroll Vacuum Pump Installation Startup 1. Check that the inlet screen is installed before begin- Safety ning operation. Do not remove or modify any safety or insulating equip- WARNING Do not insert a finger or any foreign ment from the pump. To do so may create a serious safety object in the path of the fan;...
  • Page 17: Idp-7 Power Cord Selection

    This pump is equipped with a power cord that has a Table 2 IDP-7 Power Cord Selection grounding wire with an appropriate grounding plug. The plug must be inserted into an outlet that is properly...
  • Page 18: Start Current

    IDP-7 Dry Scroll Vacuum Pump Start Current Table 3 lists the typical IDP-7 maximum starting current and duration. Table 3 Typical IDP-7 Maximum Starting Current (A) Frequency High Voltage Range 100 V 120 V 127 V 200 V 230 V 240 V...
  • Page 19: Mechanical Connections

    The IDP-7 has an optional integral automatic isolation last allows for air flow through the brass orifice. There is valve. If the IDP-7 is equipped with this valve, an internal no need to remove the brass orifice. timer opens the valve 30 seconds after the pump is switched ON.
  • Page 20: Operation

    IDP-7 Dry Scroll Vacuum Pump Operation Cleaning the Pump Unlike conventional oil-sealed pumps, Agilent dry scroll pumps do not contain fluid for the cleansing of accumu- lated dust and debris. Run the pump periodically at atmo- sphere for a minute or two to flush it out. Until...
  • Page 21: Troubleshooting

    Seal, or Part Replacement The IDP-7 is equipped with an auto-reset thermal motor protector. This protector will automatically shut down the pump when it detects an overload condition, and will automatically restart the pump when the motor has cooled to...
  • Page 22: Maintenance

    O-rings, and can be obtained from your Cleaning Agilent dealer. Table 5 Accessories and Replacement Kits Exterior The exterior surfaces of the IDP-7 may be cleaned with a Part Description Contents cloth slightly moistened with water. If necessary alcohol Number or a mild detergent may be used instead.
  • Page 23: Exploded View Of Pump Body

    IDP-7 Dry Scroll Vacuum Pump 3. Using a crescent wrench, remove the exhaust adapter 4. Cut the Tip Seal about 1/8" (3 mm) from the groove (item 2). end. 4. Remove the front cowling and hang out of the way 5.
  • Page 24 IDP-7 Dry Scroll Vacuum Pump 1. Front Cowling Bolts; M8 (3) 2. Exhaust Fitting (NW16) 3. Front Cowling 4. Frame Bolts; M5 (4) 5. Scroll Housing 6. Main O-ring; Parker 2-265 Viton 7. Tip Seal for Scroll Housing 8. Tip Seal for Orbiting Scroll 9.
  • Page 25: Request For Return Health And Safety Certification

    Please follow these instructions whenever one of our products needs to be returned. Complete the attached R R equest for Return form and send it to Agilent Technologies (see below), taking particular care to include the completed H H ealth and Safety declaration Section. No work can be started on your unit until we receive a completed copy of this form.
  • Page 26 Terms and conditions TERMS AND CONDITIONS Please read the terms and conditions below as they apply to all returns and are in addition to the Agilent Technologies Vacuum Product Division – Products and Services Terms of Sale. Unless otherwise pre-negotiated, customer is responsible for the freight charges for the returning product. Return shipments must comply with all applicable S S hipping Regulations (IATA, DOT, etc.) and carrier requirements.
  • Page 27 IDP-7 Dry Scroll Vacuum Pump Vacuum Products Division Request for Return Form Customer information Company : Contact Name: Address: Tel: Fax: Email: Equipment Product description Agilent PartNo Agilent Serial No Original Purchasing Reference Failure description Type of process (for which the equipment was used)

Table of Contents