Model
E9NC-TA0
Control output
2
Display resolution
Minimum 0.1μm
Turn off the power supply, check whether the Communication
Connection method
Communication Unit compatible wire-saving connector
Unit compatible wire-saving connector is short circuited or not,
Power supply voltage
Supplied from the connector through the communications units.
and then turn on the power supply again.
Power consumption
Power supply voltage 24V:Normal mode: 2040mW max.(Power consumption 85mA max.)
Eco function ON: 1800mW max.(Power consumption 75mA max.)
Eco function LO: 1920mW max.(Power consumption 80mA max.)
Control output
Please refer to the specification of a communication unit.
Protection circuit
Power supply reverse polarity protection, output short-circuit protection
Ambient temperature
Operating: 1 to 2 amplifiers connected: 0℃ to 55℃, 3 to 10 amplifiers connected: 0℃ to 50℃,
range
11 to 16 amplifiers connected: 0℃ to 45℃, 17 to 30 amplifiers connected: 0℃ to 40℃
Turn on the power supply again.
If the restoration fails, restart the settings.
Storage: -30℃ to 70℃ (with no icing or condensation)
If the problem still persists, it indicates a setting memory
Ambient humidity range
Operating and storage: 35% to 85% RH (with no condensation)
failure. Replace the Unit with a new one.
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC, 50/60 Hz, 1 minute
Vibration resistance
10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X and Y directions
Shock resistance
150 m/s
Weight (packed state/sensor)
Approx. 65 g/Approx. 25 g
Materials
Case and cover: Polycarbonate (PC)
2
, for 3 times each in X, Y and Z directions
10.
Enabling 4 to 13
11.
12.
500
13.
Eco on
The indicators (white digital) turn OFF.
They turn ON for approx. 10 seconds and then turn OFF
by button operation.
Eco Lo
They turn ON for approx. 10 seconds and then
the indicators (white digital) turn ON
l%
e c%
with low brightness.
Eco function LO

Suitability for Use

Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer's application or use of the Product. At Buyer's request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer's application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
OMRON Corporation
Industrial Automation Company
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
s
D
O c t, 20 14
E9NC-TA0

Advertisement

loading