Iot status monitoring amplifier

Advertisement

Quick Links

New Product
IoT Status Monitoring Amplifier
E9NC-AA/VA
IoT Status Monitoring Amplifiers for
General-purpose Analog Outputs Are
Connectable to Various Sensors
• General-purpose input: Connectable to sensor heads with
analog output between 1 to 5 VDC (voltage) or 4 to 20 mA DC
(current) for measurements.
• Scaling: Convert analog input to a desired value for display
(Upper limit setting: -1999.9999 to 9999.9999)
• No. of connectable units: Max. 30
* The maximum number of connectable units varies depending on conditions
such as the current consumption of the sensor head.
Refer to the Safety Precautions on
page 7.
Ordering Information
Amplifier unit
[Refer to Dimensions on page 9.]
Type
Appearance
Current input
Voltage input
* A Sensor Communications Unit is required if you want to use the Amplifier Unit on a network.
*
Connection method
Connector for Sensor
2 outputs
Communications Unit
Connector for Sensor
Communications Unit
Pre-wired (2 m)
Connector for Sensor
2 outputs
Communications Unit
Connector for Sensor
Communications Unit
Pre-wired (2 m)
For the most recent information on models that have been
certified for safety standards, refer to your OMRON website.
Output
NPN output
E9NC-AA0
1 output
E9NC-AA10 2M
E9NC-VA0
1 output
E9NC-VA10 2M
Model
PNP output
E9NC-AA40 2M
E9NC-VA40 2M
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron E9NC-AA0

  • Page 1 * The maximum number of connectable units varies depending on conditions For the most recent information on models that have been such as the current consumption of the sensor head. certified for safety standards, refer to your OMRON website. Refer to the Safety Precautions on page 7.
  • Page 2: Accessories (Sold Separately)

    Shallow type, total length: 0.5 m PFP-100N2 Deep type, total length: 1 m Note: For details, refer to DIN Track on PFP-@ which can be accessed from your OMRON website. End Plate [Refer to Dimensions on page 10.] Two End Plates (PFP-M) are provided with the Sensor Communications Unit.
  • Page 3: Ratings And Specifications

    E9NC-AA/VA Ratings and specifications Current input Voltage input Types Model for Sensor Communications Unit NPN output E9NC-AA10 E9NC-VA10 E9NC-AA0 E9NC-VA0 Item PNP output E9NC-AA40 E9NC-VA40 Connector for Sensor Connector for Sensor Connector for Sensor Connector for Sensor connection method Communications Unit...
  • Page 4 PLC via the network. *4. This is the case of connecting with OMRON NJ series. For details, refer to the communication unit manual. *5. The bank is not reset by the user reset function or saved by the user save function.
  • Page 5: I/O Circuit Diagrams

    Sensor Head Wiring Pin arrangement Terminal No. Signal Name Signal Sensor power supply (24 V) Sensor power supply (0 V) A IN Analog input Note: Use XN2A-1670 as the sensor-side connector for connecting amplifier units. Refer to your OMRON website for details.
  • Page 6 E9NC-AA/VA Nomenclature [NO/NC Indicator (Orange)] [ZERO Indicator: Green] Indicates the current Turn ON when the zero reset is Effectiveness. NO/NC setting status. [ST Indicator: Blue] [OUT Indicator: Orange] Turns ON when Smart Tuning is in progress. Turn ON when the judgment output is ON.* Output Switching [NO/NC] Button...
  • Page 7: Safety Precautions

    E9NC-AA/VA Safety Precautions Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/. Warning Indications • Connect the load correctly. • Do not miswire such as the polarity of the power supply. Warning level • Do not use the product if the case is damaged.
  • Page 8 E9NC-AA/VA Precautions for Correct Use Mounting the Amplifier Units • Be sure to mount the unit to the DIN track until it clicks. • When using a connector type product, place a protective label on Mounting on DIN Track the power supply connecting terminals that are not used, to 1.
  • Page 9 E9NC-AA/VA (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Amplifier Units E9NC-AA0/-VA0 NO/NC INDICATOR ZERO INDICATOR OUT2 OPTIONAL INDICATOR ST INDICATOR 30.2 27.8 OUT2 INDICATOR OUT1 INDICATOR MEASURED DATA DISPLAY 13.8 OUT1 OPTIONAL...
  • Page 10 E9NC-AA/VA DIN Track PFP-100N PFP-50N ±0.15 ±0.3 ±0.15 (5)* 1,000 (500)* *Dimensions in parentheses are for the PFP-50N. Material: Aluminum PFP-100N2 29.2 ±0.3 1,000 Material: Aluminum End Plate PFP-M M4×8 11.5 panhead screw M4 spring washer 35.5 35.3 Materials: Iron, zinc plating End Plate E39-EP1 M4×8...
  • Page 11: Terms And Conditions Agreement

    Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements.
  • Page 12 The Netherlands Hoffman Estates, IL 60169 U.S.A. Tel: (31)2356-81-300/Fax: (31)2356-81-388 Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 © OMRON Corporation 2018 All Rights Reserved. OMRON (CHINA) CO., LTD. OMRON ASIA PACIFIC PTE. LTD. In the interest of product improvement, Room 2211, Bank of China Tower, No.

Table of Contents