22 | Outdoor Unit Installation
Step 3: Anchor outdoor unit
The outdoor unit can be anchored to the
ground or to a wall-mounted bracket.
UNIT MOUNTING DIMENSIONS
The following is a list of different outdoor unit
sizes and the distance between their
mounting feet. Prepare the installation base
of the unit according to the dimensions below.
Outdoor Unit Dimensions (mm)
770x555x300 (30.3"x21.85"x11.81") (2,6 kW Type)
800x554x333 (31.5"x21.8"x13.1") (3,5 & 5,3 kW Types)
845x700x340 (33.25"x27.5"x13.38") (7 kW Type)
If you install the unit on the ground or on a concrete
mounting platform, do the following:
1. Mark the positions for four expansion bolts based on
dimensions in the Unit Mounting Dimensions chart.
2.
Pre-drill holes for expansion bolts.
3.
Clean concrete dust away from holes.
4.
Place a nut on the end of each expansion bolt.
5. Hammer expansion bolts into the pre-drilled holes.
6 720 869 159 (2016/12)
W x H x D
Fig. 5.5
Distance A (mm)
487 (19.2")
514 (20.24")
540 (21.26")
6. Remove the nuts from expansion bolts, and place outdoor
unit on bolts.
7. Put washer on each expansion bolt, then replace the nuts.
8.
Using a wrench, tighten each nut until snug.
WARNING
WHEN DRILLING INTO CONCRETE, EYE PROTECTION IS
RECOMMENDED AT ALL TIMES.
Mounting Dimensions
Distance B (mm)
298 (11.73")
340 (13.39")
350 (13.8")