Special considerations for extreme weather
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90° angle to the direction of the
wind. If needed, build a barrier in front of the unit to protect it from
extremely heavy winds.
See Fig. 22 and Fig. 23 below.
Strong wind
Fig. 22.
Fig. 23.
If the unit is frequently exposed to heavy rain or snow:
Build a shelter above the unit to protect it from the rain or snow. Be
careful not to obstruct air flow around the unit.
If the unit is frequently exposed to salty air (coastal area):
Use outdoor unit that is specially designed to resist corrosion.
1.10

Step 2: Install drain joint

Heat pump units require a drain joint. Before bolting the outdoor unit
in place, you must install the drain joint at the bottom of the unit. Note
that there are two different types of drain joints depending on the type
of outdoor unit.
If the drain joint comes with a rubber seal (see Fig. 24 - A), do the
following:
1. Fit the rubber seal on the end of the drain joint that will connect to
the outdoor unit.
2. Insert the drain joint into the hole in the base pan of the unit.
3. Rotate the drain joint 90° until it clicks into place facing the front of
the unit.
4. Connect a drain hose extension (not included) to the drain joint to
redirect water from the unit during heating mode.
If the drain joint does not come with a rubber seal (see Fig. 24 - B),
do the following:
1. Insert the drain joint into the hole in the base pan of the unit. The
drain joint will click into place.
2. Connect a drain hose extension (not included) to the drain joint to
redirect water from the unit during heating mode.
Climate 5000 – 6720886909 (2018/04)
Strong wind
Fig. 24.
Wind Baffle
In cold climates
In cold climates, make sure that the drain hose is as vertical as possible
to ensure swift water drainage. If water drains too slowly, it can freeze in
the hose and flood the unit.
1.11
The outdoor unit can be anchored to the ground or to a wall-mounted
bracket.
Strong wind
Unit mounting dimensions
The following is a list of different outdoor unit sizes and the distance
between their mounting feet.
Prepare the installation base of the unit according to the dimensions
below.
Fig. 25.
Base pan hole of
outdoor unit
Seal
Seal
Drain joint
(A)

Step 3: Anchor outdoor unit

A
Air inlet
Air outlet
W
Outdoor Unit Installation
(B)
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Climate 5000 rac 3,5-2 ouClimate 5000 rac 2,6-2 ibwClimate 5000 rac 3,5-2 ibwClimate 5000 rac 2,6-2 oueClimate 5000 rac 3,5-2 oueClimate 5000 rac 5,3-2 ibw ... Show all

Table of Contents