4.

Indoor Unit Installation

Installation Instructions - Indoor Unit
PRIOR TO INSTALLATION
Before installing the indoor unit, refer to the label on the product box to
make sure that the model number of the indoor unit matches the model
number of the outdoor unit.
Step 1: Select installation location
Before installing the indoor unit, you must choose an appropriate
location. The following are guidelines that will help you choose an
appropriate location for the unit.
following guidelines with help ensure a better installation and user
experience:
Good air circulation
Convenient drainage
Noise from the unit will not disturb other people
Firm and solid—the location will not vibrate
Strong enough to support the weight of the unit
A location at least one meter from all other electrical devices
(e.g., TV, radio, computer)
Installation Manual
DO NOT install unit in the following locations:
Near any source of heat, steam, or combustible gas
Near flammable items such as curtains or clothing
Near any obstacle that might block air circulation
Near the doorway
In a location subject to direct sunlight
NOTE ABOUT WALL HOLE:
If there is no fixed refrigerant piping:
While choosing a location, be aware that you should leave ample room
for a wall hole (see Drill wall hole for connective piping step) for the
signal cable and refrigerant piping that connect the indoor and outdoor
units. The default position for all piping is the right side of the indoor unit
(while facing the unit). However, the unit can accommodate piping to
both the left and right.
Indoor Unit Installation | 11
6 720 869 159 (2016/12)