Montigo H38SVO-ST Series Installation & Maintenance Manual

45,000 btu/hr natural gas or propane gas
Hide thumbs Also See for H38SVO-ST Series:

Advertisement

1042
1
41
16 "
654
3
25
4 "
DIMENSIONS TOLERANCES ARE IN:
WARNING:
METRIC - MM
1.6 MM
IMPERIAL - FRACTIONAL
1/16"
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a qualified
installer, service agency or the gas fitter.
WARNING
Do not store or use gasoline or any other flammable vapours or
liquids in the vicinity of this or any other gas burning appliance. A fire
or explosion may occur resulting in serious injury, property damage
or death
WARNING
FOR OUTDOOR USE ONLY
Installation & Maintenance Manual
®
C
US
H38-SVO / HL38-SVO
December 5, 2017
DATE:
H38SVO-ST,
45,000 BTU/hr Natural Gas or Propane Gas
HL38SVO-ST,
45,000 BTU/hr Natural Gas or Propane Gas
• The installation of this fireplace must be done by a
qualified and certified gas appliance installer.
• Check local codes and read all instructions prior to
installation.
NOTICE
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
Installation and service must be performed by a qualified installer,
service agency or the gas fitter.
WARNING
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odour.
Using it in an enclosed space can kill you. Never use this appliance in
an enclosed space such as a camper, tent, car or home.
WARNING
Some materials used in the manufacturing process of this product can
expose you to Benzene which is known in the State of California to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65warnings.ca.gov
XG0817

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H38SVO-ST Series

  • Page 1 Installation & Maintenance Manual H38SVO-ST, 45,000 BTU/hr Natural Gas or Propane Gas HL38SVO-ST, 45,000 BTU/hr Natural Gas or Propane Gas 6 " • The installation of this fireplace must be done by a 1042 qualified and certified gas appliance installer. ® 16 " • Check local codes and read all instructions prior to installation. 4 " NOTICE 6 " H38-SVO / HL38-SVO DIMENSIONS TOLERANCES ARE IN: WARNING: METRIC - MM...
  • Page 2: Safety Alert Key

    Introduction Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 3: Table Of Contents

    General Contents Safety Alert Key .................. 2 Introduction ..................2 Section A: Before You Begin ...............4 Installation Checklist ..................4 Section 1: Product Dimensions ............5 Unit Dimensions .....................5 Section 2: Framing ................6 Installing The Fireplace ..................6 Framing (without surround) .................6 Clearances ......................6 Back framing dimensions ................6 Fireplace Facing ....................6...
  • Page 4: Section A: Before You Begin

    General Section A: Before You Begin Installation Checklist • Determine the desired install location of your fireplace. IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS The H*38VO-ST Ventless fireplace must be installed in accordance • See Section 2, Dimensions on Page 6, and refer to the Framing with these Instructions.
  • Page 5: Section 1: Product Dimensions

    General Section 1: Product Dimensions Unit Dimensions 24" 36⅞" Width 35⅝" Opening 24" 6¾" 1¼" 36½" 5¾" Height Opening 1" 5¼" 36⅞" Width Figure 1. Fireplace dimensions XG0817...
  • Page 6: Section 2: Framing

    Installation Section 2: Framing 41" Surrounding construction Installing The Fireplace Back framing dimensions (bottom, sides and top) must be non-combustible materials, metal studs, concrete board The fireplace must be installed in a location that maintains Note: ONLY Non-combustible materials must be used in and concrete, brick, or stone.
  • Page 7: Section 2B: Optional Enclosure

    Installation Section 2b: Optional Enclosure Optional Enclosure Dimensions 16 " 1128 16 " 16 " 16 " 16 " 1042 25" 16 " 1092 43" 4 " 16 " H38-SVO / HL38-SVO DIMENSIONS TOLERANCES ARE IN: METRIC - MM 1.6 MM Figure 3. Fireplace dimensions with optional Stainless Steel enclosure. IMPERIAL - FRACTIONAL 1/16"...
  • Page 8: Section 3: Wiring

    Note: The switch location must not exceed 30' from the fireplace. WARNING Use Montigo Part No. #RPOVO Water-tight electrical box, or equivalent equipment. Ensure the box is installed in a dry location and avoid any moisture. If you install 115V Wire, ensure you use Ground fault breakers.
  • Page 9: Section 4: Installing The Gas Line

    • To check pressures, control valves have a provision to remove a 1/8” N.PT. plug to be fitted with a hose barb. • Montigo requires a service shut off valve be located in an accessible 3” location to isolate the gas supply.
  • Page 10: Section 5: Installing & Removing The Door

    Installation Section 5: Installing & Removing the Door Removing the door STEP 4: The doors are removed in a few simple steps. Follow these below to Ensure the tool is firmly remove the horizontal access panel, unlatch the door buckles and, in the lower end of the remove the door. Replace in reverse order. slot, (as shown), Then pull toward you.
  • Page 11: Section 6: Installing The Accessories

    Installation Section 6: Installing the Accessories Installing the Logs and Embers Installing the Glass Beads Bottom Logs The HL38VO-ST* is supplied with Designer Glass beads. Remove the Door as shown on page 10. The H38VO-ST* is supplied with eight (8) fibre logs. The two small bottom logs ("A"...
  • Page 12: Section 7: Start-Up Sequence

    Installation Section 7: Start-up Sequence Standing (Continuous) Pilot Ignition (SIT NOVA 820) with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. C.
  • Page 13 Installation Honeywell Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. A.
  • Page 14: Lighting Instructions

    Operation Lighting Instructions General Cleaning • Have the fireplace and installation inspected yearly. The When the fireplace is first activated, there may be some smoking inspection must include, but is not limited to, the following: and a visible film may be left on the glass. This is a normal condition, and is the result of burning of protective coatings on new metal.
  • Page 15: Gas Control Valve

    Check wiring diagram figure 14. All service and repairs should be performed by a qualified Main burner will 1. Check wiring Technician. not light 2. Check wall switch for proper connection. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. XG0817...
  • Page 16: Appendix B: Warranty

    (collectively referred to herein as "The Companies"), warrants the option, replace or repair defective components of the appliance Montigo gas appliance (referred to herein as 'the appliance') to manufactured by the company at no charge and will also pay for...
  • Page 17 In the event the installing dealer is unavailable, contact your nearest authorized Montigo dealer (www.Montigo.com) or contact Montigo direct at techsupport@ montigo.com. Ensure you have your sales receipt and the model and serial number of your appliance.
  • Page 18 Appendix Appendix C: Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as 4. INSPECTION. The state or local gas inspector of the side wall follows: horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes...
  • Page 19 Notes XG0817...
  • Page 20 Installation & Maintenance Manual H38VO ST Ventless Outdoor See Through Residential Gas Fireplace XG0817...

Table of Contents