General Data - 3, 4 Ton Standard Efficiency - Trane Voyager Manual

Product
Table of Contents

Advertisement

Table 9-1
General Data
Cooling Performance
1
Gross Cooling Capacity
SEER
2
Nominal CFM / ARI Rated CFM
ARI Net Cooling Capacity
System Power (KW)
3
Heating Performance
Heating Models
Heating Input (Btuh)
Heating Output (Btuh)
4
AFUE %
Steady State Efficiency (%)
No. Burners
No. Stages
Gas Connection Pipe Size (in.)
Compressor
No./Type
Sound Rating (BELS)
5
Outdoor Coil - Type
Tube Size (in.) OD
Face Area (sq ft)
Rows/FPI
Indoor Coil - Type
Tube Size (in.)
Face Area (sq ft)
Rows/FPI
Refrigerant Control
Drain Connection No./Size (in.)
Outdoor Fan - Type
No. Used/Diameter (in.)
Drive Type/No. Speeds
CFM
No. Motors/HP
Motor RPM
Indoor Fan - Type
No. Used/Diameter (in.)
Drive Type/No. Speeds
No. Motors
Motor HP (Standard/Oversized)
Motor RPM (Standard/Oversized)
Motor Frame Size (Standard/Oversized)
Filters - Type
Furnished? - Downflow
Horizontal
(No.) Size Recommended
6
Refrigerant Charge (Lbs of R-22)
NOTES
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and
includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Rated in accordance with ARI Standard 210/240 or 360.
2. SEER is rated at ARI conditions and in accordance with DOE test procedures.
3. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings
shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
4. AFUE is rated in accordance with DOE test procedures.
5. Sound Rating is rated in accordance with ARI Standard 270 or 370.
6. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
7. YCH048C model requires (2) 16 x 25 x 1 filters.
Indicates both downflow and horizontal units.
General
Data
3 Ton Downflow Units
YCD036C1
YCD036C3, C4
37,400
10.00
1200/1200
1200/1200
36,000
4.01
Low
High
Low
80,000
120,000
80,000
62,000
94,000
65,000
78
78
81
80
80
81.0
1
1
1/2
1/Climatuff®
1/Climatuff
8.2
Hi-Performance
Hi-Performance
.375
5.87
2/16
Hi-Performance
Hi-Performance
.375
3.67
2/15
Short Orifice
Short Orifice
1/ 3/4 PVC
1/ 3/4 PVC
Propeller
1/24
Direct/1
3150
1/.25
850
FC Centrifugal
FC Centrifugal
1/9 X 9
Direct/2
1
.33/.40
1075/1400
1075/1400
48/48
Throwaway
Throwaway
Yes
(2) 20 X 25 X 1
(2) 20 X 25 X 1
5.6
9
3, 4 Ton
Standard Efficiency
4 Ton Downflow and Horizontal Units
YC 048C1
37,400
49,900
10.00
10.00
1600/1600
36,000
48,000
3.99
5.34
High
Low
120,000
90,000
97,000
70,000
81
78
81.0
80.0
1
1
1
1
1/2
1/2
1/Climatuff
8.2
8.6
Hi-Performance
.375
.375
5.87
7.43
2/16
2/16
Hi-Performance
.375
.375
3.67
4.83
2/15
2/15
Short Orifice
1/ 3/4 PVC
Propeller
Propeller
1/24
1/24
Direct/1
Direct/1
3150
3940
1/.25
1/.33
850
1075
FC Centrifugal
1/9 X 9
1/12 X 9
Direct/2
Direct/2
1
1
.33/.40
.50/.75
850/1040
48/48
48/48
Throwaway
Yes
Yes
Yes
(2) 20 X 25 X 1
5.6
6.6
YC 048C3, C4, CW
48,900
10.00
1600/1600
47,000
5.26
High
Low
High
120,000
90,000
120,000
94,000
73,000
97,000
78
81
81
80.0
81.0
81.0
1
1
1/2
1/Climatuff
8.6
Hi-Performance
.375
5.87
2/16
Hi-Performance
.375
4.83
2/15
Short Orifice
1/ 3/4 PVC
Propeller
1/24
Direct/1
3630
1/.33
1075
FC Centrifugal
1/12 X 9
Direct/2
1
.50/.75
850/1040
48/48
Throwaway
Yes
Yes
7
(2) 20 X 25 X 1
7
5.6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents