General Data - 7, , , , , 7½ Ton High Efficiency - Trane Voyager Manual

Product
Table of Contents

Advertisement

Table 17-1
General Data
Cooling Performance
1
Gross Cooling Capacity
EER
2
Nominal CFM / ARI Rated CFM
ARI Net Cooling Capacity
3
Integrated Part Load Value
System Power (KW)
Heating Performance
4
Heating Models
Heating Input (Btuh)
1st Stage (2 Stage Only)
Heating Output (Btuh)
1st Stage (2 Stage Only)
5
AFUE%
Steady State Efficiency (%)
5
No. Burners
No. Stages
Gas Connection Pipe Size (in.)
Compressor
No./Type
Sound Rating (BELS)
6
Outdoor Coil - Type
Tube Size (in.) OD
Face Area (sq ft)
Rows/FPI
Indoor Coil - Type
Tube Size (in.)
Face Area (sq ft)
Rows/FPI
Refrigerant Control
Drain Connection No./Size (in.)
Outdoor Fan - Type
No. Used/Diameter (in.)
Drive Type/No. Speeds
CFM
No. Motors/HP
Motor RPM
Indoor Fan - Type
No. Used/Diameter (in.)
Drive Type/No. Speeds
No. Motors
Motor HP (Standard/Oversized)
Motor RPM (Standard/Oversized)
Motor Frame Size (Standard/Oversized)
Filters - Type
Furnished?
(No.) Size Recommended
7
Refrigerant Charge (Lbs of R-22)
NOTES:
1.
Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net
and includes the effect of fan motor heat. Rated in accordance with ARI Standard 210/240 or 360
2.
EER is rated at ARI conditions and in accordance with DOE test procedures.
3.
Integrated Part Load Value is based On ARI Standard 210/240 or 360. Units are rated at 80 F ambient, 80 F entering dry bulb, and 67 F entering wet bulb at ARI rated cfm.
4.
Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards.
Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
5.
AFUE and Steady State Efficiency is rated in accordance with DOE test procedures.
6.
Sound Rating is rated in accordance with ARI Standard 270 or 370.
7.
Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
8.
YCH High Heat models 2.0 is the Standard Motor.
9.
YCH091, High Heat EER is 9.70, IPLV is 9.8 and System Power is 8.25 KW, and ARI Net Cooling Capacity is 80,000 Btuh.
Indicates both downflow and horizontal units.
General
Data
7 Ton Downflow and Horizontal Units
YC 086C3,C4
82,000
9.50
2,500/2,188
78,000
8.21
Low
High
120,000
205,000
150,000
97,000
166,000
122,000
81.0
81.0
81.0
81.0
1
1
1
2
1/2
1/2
1/Climatuff®
8.80
Hi-Performance
0.375
14.00
2/16
Hi-Performance
0.375
7.88
3/15
Short Orifice
1/3/4 PVC
Propeller
1/24
Direct/1
5,620
1/.50
1075
FC Centrifugal
1/12 x 9
BELT/1
1
1.0/2.0
1725/1725
56/56
Throwaway
Yes
(3)16 X 25 X 1
11.60
17
7, , , , , 7½ Ton
High Efficiency
7½ Ton Downflow and Horizontal Units
YC 091D3,D4
86,000
10.00
9
3,000/2,625
81,000
9
9
10.10
8.10
9
Low
High
120,000
205,000
150,000
97,000
166,000
122,000
81.0
81.0
81.0
81.0
1
1
1
2
1/2
1/2
2/Climatuff
8.80
Hi-Performance
0.375
14.00
2/16
Hi-Performance
0.375
7.88
3/15
Short Orifice
1/ 3/4 PVC
Propeller
1/24
Direct/1
5,620
1/.50
1075
FC Centrifugal
1/ 12 x 9
BELT/1
1
1.0/2.0
8
1725/1725
8
8
56/56
Throwaway
Yes
(3)16 X 25 X 1
6.40/Circuit