Table of Contents
loading

Summary of Contents for Trane Voyager 27½ to 50 Ton

  • Page 1 Packaged Rooftop Air Conditioners 27½ to 50 T on - 60 Hz 23 to 42 T on (81-148 kW) - 50 Hz ™ Voyager Commercial with ™ ReliaT el Controls RT-PRC007-EN November 2006...
  • Page 2: Introduction

    Packaged Rooftop products available in are competitively priced. Trane delivers the market today. Trane was the first to with Voyager Commercial. introduce the Micro—microelectronic unit controls—and has continued to improve Voyager Commercial features cutting and revolutionalize this design concept.
  • Page 3: Table Of Contents

    Contents Introduction Features and Benefits Application Considerations Selection Procedure Model Number Description General Data Performance Data Performance Adjustment Factors Controls Electric Power Dimension and Weights Mechanical Specifications RT -PRC007-EN...
  • Page 4: Features And Benefits

    • Manual fresh air damper • Factory installed and commissioned • Economizer with dry bulb control ReliaTel™ controls • Economizer with reference enthalpy • Trane 3-D™ Scroll Compressors control • Dedicated downflow or horizontal • Economizer with differential configuration (comparative) enthalpy control •...
  • Page 5 400,000 hours of laboratory testing and Research field operation. This work combined with Simple Design with 70% Fewer Parts over 25 patents makes Trane the With over twenty years of development Fewer parts than an equal capacity worldwide leader in air conditioning...
  • Page 6 ReliaT el Makes Installing and ReliaTel features expanded diagnostic Servicing Easy capabilities when utilized with Trane Integrated Comfort™ Systems. ReliaTel eliminates the need for field installed anti-shortcycle timer and time Some Zone Sensor options have central delay relays.
  • Page 7 Voyager Commercial equipment with a Trane Tracer Summit™ or a 3rd party Generally available only on sophisticated building automation system. larger models, this Voyager Commercial...
  • Page 8 Every unit receives a 100% unit run test multiple burner system. before leaving the production line to The hot surface ignitor is a gas ignition make sure it lives up to rigorous Trane device which doubles as a safety device requirements. RT-PRC007-EN...
  • Page 9 The Conversionless Units unloading characteristics of a Trane FC The dedicated design units (either fan with inlet guide vanes result in downflow or horizontal) require no panel superior part load performance.
  • Page 10: Application Considerations

    Trane rooftops are designed to operate capabilities of the supply fan system. It is between 40 and 90 degrees Fahrenheit The rpm is correct as selected — 668 Trane’s experience that a non-modulating...
  • Page 11 651 rpm. capabilities of the supply fan system. The supply or exhaust fan on a rooftop for experience of Trane is that a non- elevations and temperatures other than modulating exhaust fan selected for 40 to standard is as follows: Bhp = 5.51 x 0.86 = 4.74 bhp actual.
  • Page 12 Trane sales engineer. elbow rather than the inside. If the roof structure is very light, roof When two or more units are to be placed...
  • Page 13: Selection Procedure

    Selection Procedure 60 Hz Selection of Trane commercial air A psychrometric chart can be used to conditioners is divided into five basic more accurately determine the mixture 2” Hi-efficiency throwaway filters. areas: temperature to the evaporator coil. Step 4 — Determine total required unit Exhaust fan.
  • Page 14 Selection Procedure 60 Hz Heating capacity selection: Table PD-9 also shows an air The supply air fan motor selected in the previous cooling capacity determination temperature rise of 23.6 F for 12,000 cfm through the 90 kw heat module. example was 7.27 bhp with 652 rpm. Winter outdoor design conditions—5 F .
  • Page 15 Selection Procedure 50 Hz Selection of Trane commercial air Step 1 – A summation of the peak cooling Step 4 – Determine total required unit conditioners is divided into five basic load and the outside air ventilation load cooling capacity: areas: shows: 22.5 tons + 1.27 tons = 23.77 (79...
  • Page 16 Selection Procedure 50 Hz Table PD-22 also shows an air To select the drive, enter Table PD-28 for a Winter outdoor design conditions – temperature rise of 21.2°F for 10,000 cfm 305 unit. Select the appropriate drive for 0°F (17.7°C). through the 67 kW heat module.
  • Page 17: Model Number Description

    D = 0-100% Economizer, Reference Convenience Outlet 0 = No Heat (TC only) Enthalpy Control F = Trane Communication Interface (TCI) L = Low Heat (YC only) E = 0-100% Economizer, Differential G = Ventilation Override H = High Heat (YC only)
  • Page 18 500 = 41.7 Tons (148 kW) Convenience Outlet 4 = 20 Hp Std. Eff. (14.9 kW) F = Trane Communication Interface (TCI) Digit 7 – Major Development Sequence Digit 14 – Supply Air Fan Drive Selections G = Ventilation Override...
  • Page 19: General Data

    General Data 60 Hz Table GD-1 — General Data — 27½ - 30 Tons 27½ Ton 30 Ton Cooling Performance Nominal Gross Capacity 329,000 363,000 Natural Gas Heat High High Heating Input (BTUH) 350,000 600,000 350,000 600,000 First Stage 250,000 425,000 250,000 425,000...
  • Page 20 General Data 60 Hz Table GD-2— General Data — 35-40 Ton 35 Ton 40 Ton Cooling Performance Nominal Gross Capacity 417 ,000 513,000 Natural Gas Heat High High Heating Input (BTUH) 350,000 600,000 400,000 800,000 First Stage 250,000 425,000 300,000 600,000 Heating Output (BTUH) 283,500...
  • Page 21 General Data 60 Hz Table GD-3— General Data — 50 Ton Table GD-4 — Economizer Outdoor Air 50 Ton Damper Leakage (Of Rated Airflow) Cooling Performance ΔP Across Dampers (In. WC) Nominal Gross Capacity 616,000 0.5 (In.) 1.0 (In.) Natural Gas Heat High Standard 1.5 %...
  • Page 22 General Data 50 Hz Table GD-5 – General Data – 23-25 Tons TC/YC/TE*275 (23 Tons) TC/YC/TE*305 (25 Tons) Cooling Performance Nominal Gross Capacity - Btu (kW) 277,000 (81.1) 303,000 (88.7) System Power - kW 24.9 28.6 kW Compressor Number/Type 2/Scroll 2/Scroll Size (Nominal Tons) 10/15...
  • Page 23 General Data 50 Hz Table GD-6 – General Data – 29-33 Tons TC/YC/TE*350 (29 Tons) TC/YC/TE*400 (33 Tons) Cooling Performance Nominal Gross Capacity(Btu) 353,000 (103.4 kW) 435,000 (127.4 kW) System Power - kW 32.55 42.6 Compressor Number/Type 2/Scroll 3/Scroll Size (Nominal Tons) 15/15 15/15/10 Unit Capacity Steps (%)
  • Page 24 General Data 50 Hz Table GD-7 – General Data – 43 Tons TC/YC/TE*500 (42Tons) Cooling Performance Nominal Gross Capacity - Btu (kW) 520,000 (152) System Power - kW 50.9 Compressor Number/Type 3/Scroll Size (Nominal Tons) 14/14/14 Unit Capacity Steps (%) 100/67/33 Motor rpm 2875...
  • Page 25: Performance Adjustment Factors

    Performance Adjustment Factors Table PD-1 – Enthalpy of Saturated Air Figure PD-1 – Air Density Ratios Wet Bulb Temperature °F °C Btu Per lb 15.23 15.70 16.17 16.66 17 .15 7 .2 17 .65 7 .8 18.16 18.68 19.21 19.75 10.0 20.30 10.6...
  • Page 26: Performance Data

    Performance 60 Hz — Standard Data Condenser Coil Table PD-4 — 27½ Ton Gross Cooling Capacities (MBh) — Standard 2-Row Condenser Coil Ambient Temperature — Deg F Entering Wet Bulb Temperature — Deg F TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC...
  • Page 27 Performance 60 Hz — Standard Data Condenser Coil Table PD-6 — 35 Ton Gross Cooling Capacities (Mbh) — Standard 2-Row Condenser Coil Ambient Temperature — Deg F 1 15 Entering Wet Bulb Temperature — Deg F TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC...
  • Page 28: Performance Data

    Performance 60 Hz — Standard Data Condenser Coil Table PD-8 — 50 Ton Gross Cooling Capacities (MBh) — Standard 2-Row Condenser Coil Ambient Temperature — Deg F Entering Wet Bulb Temperature — Deg F TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC...
  • Page 29 Performance 60 Hz — Hi Eff Data Condenser Coil Table PD-4A — 27½ Ton Gross Cooling Capacities (MBh) — High Efficiency 3-Row Condenser Coil Ambient Temperature — Deg F Entering Wet Bulb Temperature — Deg F TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC...
  • Page 30 Performance 60 Hz — Hi Eff Data Condenser Coil Table PD-6A — 35 Ton Gross Cooling Capacities (Mbh)— High Efficiency 3-Row Condenser Coil Ambient Temperature — Deg F Entering Wet Bulb Temperature — Deg F TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC...
  • Page 31: Condenser Coil

    Performance 60 Hz — Hi Eff Data Condenser Coil Table PD-8A — 50 Ton Gross Cooling Capacities (MBh) — High Efficiency 3-Row Condenser Coil Ambient Temperature — Deg F 1 15 Entering Wet Bulb Temperature — Deg F TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC...
  • Page 32 Performance Data 60 Hz Table PD-9 — Electric Heat Air Temperature Rise Total Input 8000 9000 10000 11000 12000 13000 14000 15000 16000 17000 18000 19000 20000 14.2 12.6 11.3 10.3 7 .6 — — — — — 21.2 18.9 17 .0 15.4 14.2...
  • Page 33 Performance 60 Hz Data Table PD-12 — Supply Fan Performance — 27½ - 35 Ton Static Pressure (in. wg) 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 SCFM 8000 1.17 1.62 2.09 2.55 3.11 3.75 4.42 5.09 5.77 8500 1.33 1.82 2.33...
  • Page 34 Performance Data 60 Hz Table PD-13 — Supply Fan Performance — 40 and 50 Ton Static Pressure (in. wg) 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 SCFM 12000 2.29 2.86 3.45 4.11 4.75 5.43 6.14 6.89 7 .63 13000 2.79 3.40...
  • Page 35 Performance 60 Hz Data Supply Fan Performance 27-35T Figure PD-2 — Supply Fan Performance — 27½ - 35 Ton 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 26000 Volumetric Airflow Rate(CFM) Supply Fan Performance 40 and 50 Ton Figure PD-3 —...
  • Page 36 Performance 60 Hz Data Table PD-14 — Component Static Pressure Drops (in. W.G.) Heating System Filters Nominal CFM Gas Heat Electric Heat ID Coil Throwaway High Eff. Filters Inlet Guide Tons Std Air High 1 Element 2 Element 2" 2” 4”...
  • Page 37 Performance Data 60 Hz Table PD-15 — Supply Air Fan Drive Selections 7 .5 HP 10 HP 15 HP 20 HP Nominal Drive Drive Drive Drive Tons 27½T 750* 790** 800* Note: *For YC gas/electrics only. **For TC and TE Cooling only and with electric heat units only. RT -PRC007-EN...
  • Page 38 Performance Data 60 Hz Table PD-16— Power Exhaust Fan Performance Exhaust External Static Pressure — Inches of Water Airflow High Speed Med Speed Low Speed (Cfm) 3500 0.900 — — 4000 0.860 — — 4500 0.820 — — 5000 0.780 —...
  • Page 39 Performance 50 Hz — Standard Data Condenser Coil Table PD-17 – 23 Ton Gross Cooling Capacities (MBh) — Standard Efficiency 2-Row Condenser Coil (I-P) Ambient Temperature – °F 1 15 Entering Wet Bulb Temperature – °F (°F) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 21 1 6900 7500...
  • Page 40 Performance 50 Hz — Standard Data Condenser Coil Table PD-18 – 25 Ton Gross Cooling Capacities (MBh) — Standard Efficiency 2-Row Condenser Coil (I-P) Ambient Temperature – °F Entering Wet Bulb Temperature – °F (°F) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 7500 8000 31 1...
  • Page 41 Performance 50 Hz — Standard Data Condenser Coil Table PD-19 – 29 Ton Gross Cooling Capacities (MBh) — Standard Efficiency 2-Row Condenser Coil (I-P) Ambient Temperature – °F 1 15 Entering Wet Bulb Temperature – °F (°F) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 8750 31 1 31 1...
  • Page 42 Performance 50 Hz — Standard Data Condenser Coil Table PD-20 – 33 Ton Gross Cooling Capacities (MBh) — Standard Efficiency 2-Row Condenser Coil (I-P) Ambient Temperature – °F Entering Wet Bulb Temperature – °F (°F) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 10000 41 1 41 1...
  • Page 43 Performance 50 Hz — Standard Data Condenser Coil Table PD-21 – 42 Ton Gross Cooling Capacities (MBh) — Standard Efficiency 2-Row Condenser Coil (I-P) Ambient Temperature – °F 1 15 Entering Wet Bulb Temperature – °F (°F) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 12500 31 1 13500...
  • Page 44 Performance 50 Hz — Hi Eff Data Condenser Coil Table PD-17b – 23 Ton Gross Cooling Capacities (MBh) — High Efficiency 3-Row Condenser Coil (I-P) Ambient Temperature – °F Entering Wet Bulb Temperature – °F (°F) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 6900 31 1 7500...
  • Page 45 Performance 50 Hz — Hi Eff Data Condenser Coil Table PD-18b – 25 Ton Gross Cooling Capacities (MBh) — High Efficiency 3-Row Condenser Coil (I-P) Ambient Temperature – °F 1 15 Entering Wet Bulb Temperature – °F (°F) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 31 1 1 18 7500...
  • Page 46 Performance 50 Hz — Hi Eff Data Condenser Coil Table PD-19b – 29 Ton Gross Cooling Capacities (MBh) — High Efficiency 3-Row Condenser Coil (I-P) Ambient Temperature – °F Entering Wet Bulb Temperature – °F (°F) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 8750 9000 10000...
  • Page 47 Performance 50 Hz — Hi Eff Data Condenser Coil Table PD-20b – 33 Ton Gross Cooling Capacities (MBh) — High Efficiency 3-Row Condenser Coil (I-P) Ambient Temperature – °F 1 15 Entering Wet Bulb Temperature – °F (°F) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 10000 21 1 11000...
  • Page 48 Performance 50 Hz — Hi Eff Data Condenser Coil Table PD-21b – 42 Ton Gross Cooling Capacities (MBh) — High Efficiency 3-Row Condenser Coil (I-P) Ambient Temperature – °F 1 15 Entering Wet Bulb Temperature – °F (°F) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 12500 51 1 41 1...
  • Page 49 Performance Data 50 Hz Table PD-22 – Electric Heat Air Temperature Rise (°F) (I-P) Heater Total Input (kW) 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 17000 26.9 12.1 10.6 7 .7 7 .1 – – – – –...
  • Page 50 Performance Data 50 Hz Table PD-25 – Supply Fan Performance – 23-29 Ton (I-P) Static Pressure (in. wg) 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 scfm 6670 0.80 1.18 1.58 2.08 2.63 3.20 3.78 4.37 4.96 7085 0.90 1.31 1.70 2.21...
  • Page 51 Performance Data 50 Hz Figure PD-4 — Supply Fan Performance — 23-29 Ton Supply Fan Performance (996) (872) (747) (623) (498) (374) (249) (125) (0.0) 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 26000 Volumetric Airflow Rate(CFM) (.94) (1.89) (2.83)
  • Page 52 Performance Data 50 Hz Table PD-26 – Supply Fan Performance – 33 and 42 Ton (I-P) Static Pressure (in. wg) 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 9996 1.46 1.95 2.49 3.04 3.64 4.25 4.92 5.59 6.23 6.90 10829 1.78...
  • Page 53 Performance Data 50 Hz Figure PD-5 – Supply Fan Performance – 33 and 42 Ton (I-P) (1245) (996) (747) (498) (249) (0.0) 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 26000 28000 Volumetric Airflow Rate(CFM) (.94) (1.89) (2.83) (3.78)
  • Page 54 Performance Data 50 Hz Table PD-27 – Component Static Pressure Drops — in. wg (I-P) Nom inal Heating Sys tem Filters Std Tons C FM Gas Heat Electric Heat ID Coil Throw aw ay High Eff. Filters Inlet Guide (kW) Std Air High 1 Elem ent 2 Elem ent...
  • Page 55 Performance Data 50 Hz Table PD-27a – Component Static Pressure Drops — Pa (SI) Nominal Heating System Filters Std Tons ID Coil Throwaway Inlet Guide Gas Heat Electric Heat High Eff. Filters (kW) Std Air High 1 Element 2 Element Adder 50 mm 100 mm Vanes...
  • Page 56 Performance Data 50 Hz Table PD-28 – Supply Air Fan Drive Selections 5 hp 7 .5 hp 10 hp 15 hp Nominal Drive Drive Drive Drive Tons (kW) 23 (80) 625* 25 (88) 29 (103) 658** 664* 33 (118) 42 (146) Note: *For YC gas/electrics only.
  • Page 57: Controls

    Controls VAV Units Only Variable Frequency Drives (VFD) Control air is not suitable for “economizing, ” the fresh air dampers drive to the minimum Variable frequency drives are driven by a Sequence of Operation open position. A field adjustable modulating 2-10 vdc signal from the VAV potentiometer on the Economizer module.
  • Page 58 Controls air temperature is more than 20 F below returned to VAV cooling mode. The comparative enthalpy. If outside air is not the reset temperature setpoint the Morning Warm-up setpoint is set at the suitable for “economizing, ” the fresh air amount of reset is equal to the reset unit mounted VAV Setpoint potentiometer dampers drive to the minimum open...
  • Page 59 Controls closed. The RTRM will cycle second stage Auto Changeover exclusive of the Trane Communications on and off as required while keeping Interface (TCI). When the System Mode is “Auto, ” the stage one energized. Control Sequences of mode will change to cooling or heating...
  • Page 60 Night Setback Sensors When this function is initiated by out to Low Voltage Terminal Board One pushing the override button on the ICS Trane’s night setback sensors are (LTB1). sensor, TRACER will switch the unit to programmable with a time clock the occupied mode.
  • Page 61: Electric Power

    Electrical Data The selection MOP value will be the larger Electrical Service Sizing then reselect the RDE value to equal the of the cooling mode MOP value or the MOP value. To correctly size electrical service heating mode MOP value calculated (Keep in mind when determining LOADS wiring for your unit, find the above.
  • Page 62 Electrical Data 60 Hz Table ED-2 — 27½-50 Ton Electrical Service Sizing Data Fan Motors Compressor Supply Condenser Exhaust Allowable Standard/ Electrical Voltage Hi-Efficiency Model Characteristics Range No/Ton (Ea.) (Ea.) (Ea.) (Ea.) TC/TE/YC*330 208/60/3 187-229 1/10,1/15 41.9/62.8 269/409 7 .5 22.3/21.5 7 .0 10.0...
  • Page 63 Electrical Data 50 Hz Table ED-4 – Electrical Service Sizing Data Fan Motors Compressor Supply Condenser Exhaust Electrical Max. Model Characteristics No/Ton (Ea.) (Ea.) (Ea.) (Ea.) MCA* Fuse Size TC/TE/YC*275 380-415/50/3 1/10, 1/15 18.1/27 .3 110/174 13.1 TC/TE/YC*305 380-415/50/3 2/15 27 .3 13.1 TC/TE/YC*350...
  • Page 64: Dimension And Weights

    Dimensional Data 60/50 Hz Figure DD-1— Fresh Air, Power Exhaust Hoods SIDE VIEW SHOWING FRESH AIR AND POWER EXHAUST HOODS FOR DOWNFLOW CONFIGURATION 2 7/16" (62) 32 1/8" (814) 37 3/4" (959) SIDE VIEW SHOWING POWER EXHAUST HOODS FOR HORIZONTAL CONFIGURATION NOTE: The Two Horizontal Power Exhaust Hoods and the three Horizontal Fresh Air Hoods are...
  • Page 65 Dimensional Data 60/50 Hz Figure DD-2 – 60 Hz 27½-35, 50 Hz 23-29 Tons (TC, TE, YC Low Heat) Note: Dimensions in ( ) are mm 1” = 25.4 mm RT -PRC007-EN...
  • Page 66 Dimensional Data 60/50 Hz Figure DD-3– 60 Hz 27½-35, 50 Hz 23-29 Tons (YC High Heat) Note: Dimensions in ( ) are mm 1” = 25.4 mm RT-PRC007-EN...
  • Page 67 Dimensional Data 60/50 Hz Figure DD-4 – 60 Hz 40-50, 50 Hz 33-42 Tons (TC, TE, YC Low & High Heat) Note: Dimensions in ( ) are mm 1” = 25.4 mm RT -PRC007-EN...
  • Page 68: Variable Air Volume Vav

    Dimensional (Variable Air Data Volume VAV) Field Installed Sensors SINGLE SETPOINT SENSOR WITH SYSTEM FUNCTION LIGHTS (BAYSENS021*) PROGRAMMABLE NIGHT-SETBACK SENSOR (BAYSENS020*) Note: 1. Remote sensors are available for use with all zone sensors to provide remote sensing capabilities. RT-PRC007-EN...
  • Page 69: Constant Volume Cv

    Dimensional (Constant Data Volume CV) Field Installed Sensors PROGRAMMABLE NIGHT-SETBACK SENSOR (BAYSENS019*) DUAL SETPOINT, MANUAL/AUTOMATIC CHANGEOVER SENSOR WITH SYSTEM FUNCTION LIGHTS (BAYSENS010*) WITHOUT LED STATUS INDICATORS (BAYSENS008*) SINGLE SETPOINT WITHOUT LED STATUS INDICATORS (BAYSENS006*) Note: 1. Remote sensors are available for use with all zone sensors to provide remote sensing capabilities. RT -PRC007-EN...
  • Page 70 Dimensional (CV and VAV) Data ™ Integrated Comfort System Sensors ZONE TEMPERATURE SENSOR W/TIMED OVERRIDE BUTTON ZONE TEMPERATURE SENSOR W/TIMED OVERRIDE BUTTONS AND LOCAL SETPOINT ADJUSTMENT (BAYSENS014) (BAYSENS013*) ALSO AVAILABLE SENSOR ONLY (BAYSENS017*) TEMPERATURE SENSOR (BAYSENS016*) REMOTE MINIMUM POSITION POTENTIOMETER CONTROL (BAYSTAT023*) Note:...
  • Page 71 Dimensional Data and Weights 1,2,3 Table W-1 — Approximate Units Operating Weights — lbs./kg Basic Unit Weights 1,2,3 WALL-MOUNTED CO SENSOR (BAYCO2K005*) Unit DUCT-MOUNTED CO SENSOR (NOT PICTURED) (BAYC02K006*) Model Low Heat High Heat **D330/275 3695/1676 4075/1848 3565/1617 3585/1626 **H330/275 3735/1694 4165/1889 3605/1635...
  • Page 72 Weights Table W-3— Approximate Operating Weights — Optional Components — lbs./kg Var. Freq. Non- Factory. 0-25% Inlet Drives (VFD’s) Thru-the Fused GFI with Hi Eff Roof Unit Baro. Power Hi Eff. Supply Guide With Serv base Discon. Discon. Cond Curb Model Relief Exhaust...
  • Page 73: Mechanical Specifications

    240 volt, Cooling performance shall be rated in Trane 3-D Scroll compressor includes wye connected for 480 and 600 volt. accordance with ARI testing procedures. centrifugal oil pump, oil level sightglass...
  • Page 74 Tracer Originated Data Shall be provided to interface with the electronic signals from sensors • Command operating mode Trane Integrated Comfort™ System and measuring indoor and outdoor • Host controllable functions: shall be available field or factory-installed. temperatures. The control algorithm...
  • Page 75: Unit Options

    Mechanical Specifications Exhaust Air Condenser Coil Guards down for field assembly and include wood nailer strips. Factory installed condenser vinyl coated Barometric Relief wire mesh coil guards shall be available Zone Sensors The barometric relief damper shall be to provide full area protection against Shall be provided to interface with the optional with the economizer.
  • Page 76 VAV units or as a zone sensor with Tracer BAYICSI004* — Field-installed Trane Integrated Comfort system. Communication Interface (TCI). BAYSENS019* and BAYSENS020* — BAYLTCI003* — Field-installed LonTalk...
  • Page 77 RT -PRC007-EN...
  • Page 80 A business of American Standard Companies www.trane.com For more information contact your local district Trane has a policy of continuous product and product data improvement and reserves the right to change design office, or e-mail us at comfort@trane.com and specifications without notice.