General Data - Trane Precedent TSC090H Service Facts

Packaged rooftop air conditioners - cooling, gas/electric. 7.5 ton standard efficiency rooftop units

Advertisement

General Data

Table 1. General data - 7.5 tons (single compressor) -
standard efficiency
(a)
Cooling Performance
Gross Cooling Capacity (400 cfm/ton)
(b)
EER
Nominal cfm/AHRI Rated cfm
AHRI Net Cooling Capacity
(c)
IEER (T/Y)
System Power (kW)
Compressor
Number/Type
Sound
Outdoor Sound Rating (dB)
Outdoor Coil - Type
Configuration
Tube Size (.in)
Face Area (sq. ft.)
Rows/FPI (Fins per inch)
Indoor Coil - Type
Configuration
Tube Size (in.)
Face Area (sq. ft.)
Rows/FPI (Fins per inch)
Refrigerant Control
Drain Connection No./Size (in.)
Outdoor Fan - Type
No. Used/Diameter (in.)
Drive Type/No. Speeds
CFM
Motor HP
Motor RPM
Indoor Fan - Type
No. Used/Diameter (in.)/Width (in.)
Drive Type/No. Speeds/RPM
Motor HP (Standard/Oversized)
Motor Frame Size (Standard/
Oversized)
(d)
Filters
Type Furnished
Number Size Recommended
(e)
Refrigerant Charge
lbs of R-410A
(f)
Heating Performance
(Gas/Electric Only)
Heating Input
Low Heat Input (Btu)
Mid Heat Input (Btu)
High Heat Input (Btu)
RT-SVF55F-EN
7.5 Tons
T/YSC090H3,4,W
92,500
11.2
3,000/2,400
87,000
12.9/12.7
7.77
1/Scroll
88
Microchannel
Full Face
1.00
16.91
1/21
Lanced
Full Face
0.3125
9.89
4/16
Thermal Expansion Valve
1¾ NPT
Propeller
1/26
Direct/1
6400
0.70
1,100
FC Centrifugal
1/12x12
Belt/Variable/1,750
1.0/3.0
56/56
Throwaway
(2) 16x25x2
7.5
120,000
150,000/105,000
200,000/140,000
Table 1. General data - 7.5 tons (single compressor) -
standard efficiency (continued)
Heating Output
Low Heat Input (Btu)
Mid Heat Input (Btu)
High Heat Input (Btu)
Steady State Efficiency%
Low Heat Input (Btu)
Mid Heat Input (Btu)
High Heat Input (Btu)
No. Burners
Low Heat Input (Btu)
Mid Heat Input (Btu)
High Heat Input (Btu)
No. Stages
Low Heat Input (Btu)
Mid Heat Input (Btu)
High Heat Input (Btu)
Gas Supply Line Pressure
Natural (minimum/maximum)
LP (minimum/maximum)
Gas Connection Pipe Size (in)
Low Heat
Mid Heat
High Heat
(a) Cooling performance is rated at 95°F ambient, 80°F entering dry bulb,
67°F entering wet bulb. Gross capacity does not include the effect of
fan motor heat. AHRI capacity is net and includes the effect of fan motor
heat. Units are suitable for operation to ±20% of nominal cfm. Units
are certified in accordance with the Unitary Air-Conditioner Equipment
certification program, which is based on AHRI Standard 340/360.
(b) EER is rated at AHRI conditions and in accordance with DOE test pro-
cedures.
(c) Integrated Efficiency Ratio (IEER) is rated in accordance with AHRI
Standard 340/360. The IEER rating requires that the unit efficiency be
determined at 100%, 75%, 50% and 25% load (net capacity) at the
specified in AHRI Standard.
(d) Optional 2" MERV 8 and MERV 13 filters also available.
(e) Refrigerant charge is an approximate value. For a more precise value,
see unit nameplate and service instructions.
(f) Heating performance limit settings and rating data were established
and approved under laboratory test conditions using American National
Standards Institute standards. Ratings shown are for elevations up to
2000 feet. For elevations above 2000 feet, ratings should be reduced
at the rate of 4% for each 1000 feet above sea level. Applicable to gas/
electric units only.
7.5 Tons
T/YSC090H3,4,W
96,000
120,000/84,000
160,000/112,000
80
80
80
3
3
4
1
2
2
4.5/14.0
11.0/14.0
1/2
3/4
3/4
5