3-1-4 Emission Intensity Control Function

This function reduces the emitting intensity.
It is useful for preventing interference from the emitter to the other devices.
Emission intensity control
‡ CLR (Ineffective) : Operating range is 0.3 to 9m for SF4B-H  SF4B-H <V2> (12 to 64 beam
‡ SET (Effective) : The operating range is reduced by approx. 50%.

3-1-5 Copy Function

This is a function to copy the setting of a SF4B / SF4B<V2> series to other SF4B / SF4B<V2> series.
7KLV IXQFWLRQ LV DYDLODEOH RQO\ XQGHU WKH VDPH V\VWHP FRQ¿JXUDWLRQ WKH QXPEHU RI VHQVRUV WKH QXP-
ber of beam channels, same model No.).
All functions that are settable with this device can be copied.
Note that the password is also copied with this function.
The following operations are available with this function.
Upload
: Upload the functional setting data of SF4B / SF4B<V2> series to this device.
Download : Download the functional setting data of this device to SF4B / SF4B<V2> series.
Monitoring : Check the functional setting data saved in this device.
SF4B / SF4B<V2> series
Original

3-1-6 Muting Setting Changing Function

The setting of the muting function can be changed.
Setting of the muting function on each beam channel
Each beam channel can be set to "effective / ineffective" in the muting function respectively. (Note)
The factory setting of this function is effective for all beam channels.
Note: If the beam channel set to ineffective in the muting function is blocked, the control output (OSSD 1 / 2) becomes "OFF" and
the muting function is canceled.
There are two setting methods, "Auto" and "Manual" to set muting beam channel.
‡ Auto setting
‡ Manual setting : Each beam channel can be set to "effective / ineffective" in the muting function.
© Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V
channels) and SF4B-A  SF4B-A <V2> (6 to 32 beam channels), 0.3 to
7m for SF4B-F  SF4B-F <V2> and SF4B-H  SF4B-H <V2> (72 to 96
beam channels) and SF4B-A  SF4B-A <V2> (36 to 48 beam channels)
(factory setting).
Upload
SF4B / SF4B<V2> series
: The beam channel which is currently blocked is set as the "effective" beam
channel. When all beam channels are in light receiving condition, the setting is
not accepted. Furthermore, in the state where emission is halted or all beam
channels are blocked, the all beam channels become "effective" in the muting
function.
ON: The muting function is effective
OFF: The muting function is ineffective
This device
(Storage area for SF4B / SF4B<V2> series)
Download