Function Setting
3-3-2 Floating Blanking Function
2. Floating blank-
Sensor selection
ing function
(All sensors)
3. To Auxiliary
output switching
function
(Main sensor)
(Sub sensor 1)
(Sub sensor 2)
FLO1 <Effective setting of beam channel>
0: Ineffective
1: 1 beam channel setting
2: 2 beam channels setting
3: 3 beam channels setting
FLO2 <Ineffective setting of both end beam channel>
6(7 (IIHFWLYH %RWK HQGV RI WKH EHDP FKDQQHOV DUH QRW VXEMHFW WR WKH ÀRDW EODQNLQJ IXQFWLRQ
&/5 ,QHIIHFWLYH $OO EHDP FKDQQHOV DUH VXEMHFW WR WKH ÀRDWLQJ EODQNLQJ IXQFWLRQ
FLO3 <Non serial beam channel setting>
SET (Effective) : Non-serial beam channel mode
CLR (Ineffective) : Serial beam channel mode
Note: When "all sensors" is selected in the sensor selection, the setting of the floating blanking function on each SF4B /
SF4B<V2> series should be identical.
27
Set No. of beam channel
Input
password
(Ineffective)
One beam
channel effecive
Two beam
channel effecive
Three beam
channel effecive
© Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V
Send
OK
NG
(Error)
Ineffective setting
Setting for non-
for
both
ends
serial
beam
beam channels
channel
(Effctive)
(Effctive)
(Ineffctive)
(Ineffctive)
To 2
Send
OK
NG
(Error)
key operation
: FUNCTION
: ENTER
: CANCEL
: -
: +
To 2