19 RECYCLING AND DISPOSAL

At the end of its useful working life, do not abandon the storage cylinder in the environment, but dispose of it through the proper
channels in accordance with applicable legislation.

20 TROUBLESHOOTING

FAULT
The storage cylinder functions incorrectly
or irregularly
CAUSE
Flow rate too high
There are blockages or deposits in the
domestic hot water circuit
The pump is malfunctioning
The water temperature from the boiler is
too low
There is air in the primary circuit
17
TECHNICAL ASSISTANCE SERVICE
SOLUTION
− Fit a pressure limiter
− Fit a flow reducer
− Check and clean as necessary
− Check the pump
− Check the temperature setting
− Bleed the circuit