3 Communications Data for CompoWay/F
Variable
Address
type
C3 (83)
0000
C3 (83)
0001
C3 (83)
0002
C3 (83)
0003
C3 (83)
0004
C3 (83)
0005
3 - 8
Parameter
name
Input Type
H'00000000 (0):
H'00000001 (1):
H'00000002 (2):
H'00000003 (3):
H'00000004 (4):
H'00000005 (5):
H'00000006 (6):
H'00000007 (7):
H'00000008 (8):
H'00000009 (9):
H'0000000A (10):
H'0000000B (11):
H'0000000C (12):
H'0000000D (13):
H'0000000E (14):
H'0000000F (15):
H'00000010 (16):
H'00000011 (17):
H'00000012 (18):
H'00000013 (19):
H'00000014 (20):
H'00000015 (21):
H'00000016 (22):
H'00000017 (23):
H'00000018 (24):
H'00000019 (25):
H'0000001A (26):
H'0000001B (27):
H'0000001C (28):
H'0000001D (29):
H'0000001E (30):
*
Selection is possible only for E5CC-U Controllers and
only if they are manufactured in May 2014 or later
(version 2.2).
Scaling Upper
Scaling lower limit + 1 to H'0000270F (Scaling lower limit +
Limit
1 to 9,999)
Scaling Lower
H'FFFFF831 to Scaling upper limit − 1 (−1999 to Scaling
Limit
upper limit − 1)
Decimal Point
H'00000000 to 00000003 (0 to 3)
Temperature
H'00000000 (0): °C
Unit
H'00000001 (1): °F
SP Upper Limit
The range of values (without decimal point) is as follows:
Temperature input: SP lower limit + 1 to Input range upper
Analog input:
Setting (monitor) value
Pt (−200 to 850°C/−300 to 1500°F)
Pt (−199.9 to 500.0°C/−199.9 to
900.0°F)
Pt (0.0 to 100.0°C/0.0 to 210.0°F)
JPt (−199.9 to 500.0°C/−199.9 to
900.0°F)
JPt (0.0 to 100.0°C/0.0 to 210.0°F)
K (−200 to 1300°C/−300 to 2300°F)
K (−20.0 to 500.0°C/0.0 to 900.0°F)
J (−100 to 850°C/−100 to 1500°F)
J (−20.0 to 400.0°C/0.0 to 750.0°F)
T (−200 to 400°C/−300 to 700°F)
T (−199.9 to 400.0°C/−199.9 to
700.0°F)
E (−200 to 600°C/−300 to 1100°F)
L (−100 to 850°C/−100 to 1500°F)
U (−200 to 400°C/−300 to 700°F)
U (−199.9 to 400.0°C/−199.9 to
700.0°F)
N (−200 to 1300°C/−300 to 2300°F)
R (0 to 1700°C/0 to 3000°F)
S (0 to 1700°C/0 to 3000°F)
B (100 to 1800°C/300 to 3200°F)
W (0 to 2300°C/0 to 3200°F)
PL II (0 to 1300°C/0 to 2300°F)
Infrared temperature sensor (K
140°F/60°C)
Infrared temperature sensor (K
240°F/120°C)
Infrared temperature sensor (K
280°F/140°C)
Infrared temperature sensor (K
440°F/220°C)
4 to 20 mA
0 to 20 mA
1 to 5 V
0 to 5 V
0 to 10 V
0 to 50 mV*
limit
SP lower limit + 1 to Scaling upper
limit
E5@C Digital Temperature Controllers Communications Manual (H175)