3. Specifications

Model
Generator Type
Rated Frequency
Rated Output(Prime)
Standby Output
Rated Voltage
Rated Current
Power Factor
Insulation class
Excitation
No. of Poles
Type
Model(Manufacturer)
No. of Cylinders
(bore × stroke)
Continuous Rated
Output
Rated Speed
Displacement
Combustion System
Cooling Method
Starting Method
Fuel
Lubricating Oil
Fuel Tank Capacity
Lubricant Volume
Cooling Water Volume
Starting Motor Capacity
Charging Alternator Capacity
Battery Capacity
Length
Width
Height
Dry Weight
Net Weight
*Specifications subject to change without notice.
**Generating application is 60Hz ONLY.
Unit
-
Hz
Three phase
Single phase
Three phase
Single phase
Three phase
Single phase
Three phase-208V
Three phase-240V
Three phase-480V
Single phase-120V
Single phase-240V
-
-
-
-
-
-
(in./mm)
hp
rpm
cu.in./liters
-
-
-
-
-
gal./liters
gal./liters
gal./liters
V-kW
V-A
V-Ah
in./mm
in./mm
in./mm
lbs./kg
lbs./kg
4
Revolving Field Brushless
kVA
kW
kVA
kW
kVA
kW
kVA
kW
V
208/240/ [480] *1
V
120/139/240/[277] *1
A
A
A
A
62.5×2 [31.3 x 2]*1
A
Three phase 0.8, Single phase 1.0
Self-Excitation (brushless)
Vertical Water-Cooled 4-Cycle Diesel
4LE2T(ISUZU)
4(3.35x3.78/85x96)
Direct injection
No.2-D,S15 EPA regulation
API service-type CJ-4 class
2.7/10.4(including filter 0.1/0.4)
2.6/10(including sub-tank 0.3/1.0)
DGK25F
60
25
20
15 [7.5] *1
15 [7.5] *1
27.5
22
16.5 [8.3] *1
16.5 [8.3] *1
60
60
30
62.5 [31.3]*1
F
4
33.5
1,800
133/2.179
(Turbo-charged)
Water cooled
Electric
51.5/195
12-2.0
12-50
12-72
63/1,603
33/850
55/1,400
1,929/875
2,359/1,070