After Repair; Elimination Of "Repair" Malfunction - Shindaiwa DGK25F Service Manual

Diesel engine generator
Hide thumbs Also See for DGK25F:
Table of Contents

Advertisement

"Monitor Lamp" Flashing – when the monitor lamp will blink 3 times and twice shorter, it shows the engine code
"32", for example.
Monitor
Lamp: ON
Monitor
Lamp: OFF
Flashing Pattern of "Monitor Lamp" – for the engine code "225";
Monitor
Lamp: ON
Monitor
Lamp: OFF

10-3 After Repair

After malfunction was repaired, eliminate the malfunction from "current" record in following steps.
1) Turn the starter switch to "RUN".
2) Start the engine and run for few minutes.
3) Turn and remain the starter switch to "STOP" position for 30 sec. at least.
4) Turn the starter switch to "RUN".
10-4 Elimination of "Past" Malfunction
"Past" malfunction has recorded in the ECM (Engine Control Module) unless it has deleted.
Follow the step below when the past "malfunction" record from the ECM should eliminate.
1) Turn the starter switch to "RUN".
2) Press and hold the "memory clear button".
3) Connect the 1-pin connector (green/blue) with a negative post (-) from the battery for 3 sec. at
least while holding the "memory clear button".
Warning
Always wear a rubber glove before connecting 1-pin connector and battery.
1
2
10th digit
1
2
1
100th digit
10th digit
3
1
2
1 digit
2
1
2
24
t1= approx.0.3 sec.
t2= approx.
0.6
sec.
t3= approx.1.2 sec.
t4= approx.2.4 sec.
4
3
5
1st digit

Hide quick links:

Advertisement

Table of Contents
loading