Response
Description of Response Code
Code
Bad File
00
Version check failed
01
Image type mismatch
02
Device type mismatch
03
Hardware type mismatch
04
General variant mismatch
05
Firmware header wrong length
Panel is Busy
20
System update pending - panel is armed
System update pending -AC trouble (Any
21
AC trouble; device/module)
System update pending -low battery (Any
22
low battery trouble; device/module)
System update pending - communication in
25
progress
Firmware Update Sequence Change
A0
System firmware update successful
A1
System firmware update failure
System firmware update failure - module
A2
not found
AA
Device firmware transfer begin
AB
Device firmware module update begin
AC
General device firmware transfer failure
Firmware Update Status
C0
System ready to update.
C1
System update cancel request received
C2
System update begin
Firmware Download Request Reject
Table 14: Response Code Descriptions and Corresponding Actions
Corresponding Action
Contact DSC Tech Support, described the action attempted with
the system and supply them with the Response Code in Section
[983].
Disarm the panel to continue with system firmware update
process.
Resolve the AC trouble to continue with system firmware
update process.
Resolve the low battery trouble to continue with system
firmware update process.
Retry in a few minutes; if issue persists, contact DSC Tech
Support.
None
At least one module was not updated. Use DLS to reapply the
firmware to the module not updated.
At least one module was not responding during firmware
update. Ensure all modules enrolled are physically connected
and powered up.
None
None
Contact DSC Tech Support, describe the action attempted with
the system and supply them with the Response Code in Section
[983].
None
The system has received an update cancel request from DLS.
None