DSC PowerSeries Neo LE2080 Installation Manual page 34

Fire alarm communicator
Table of Contents

Advertisement

[2] Parity Type Default (OFF)
ON: Odd Parity
OFF: Even Parity
[3] Stop Bits Default (OFF)
ON: Two Stop Bits
OFF: One Stop Bits
[4] Flow Control Default (OFF)
ON: Flow Control
OFF: No Flow Control
[5] - [8] Reserved
[422] Integration Identification Number
This section will display the unique 12-digit number assigned to this communicator for the identification when integrated
with third party applications.
[423]Session 1 Integration Access Code
Default (12345678) Valid Range is 00000000 - FFFFFFFF
This section is a programmable 8-digit number used for initialization with third party applications.
[424] Session 1 SMS Label
Default (11111111)
Program this section with a label that is used to validate a connection between the communicator and third party software
over cellular.
[425] Session 1 Integration Toggle Options 2
The toggle options in this section are used to enable and configure the path used for integration with third party applic-
ations.
[1] Integration Over Serial Port Default (ON)
[2] Integration Over Cellular Default (OFF)
[3] Integration Over Ethernet Default (OFF)
[4] Type 2 Encryption Default (OFF)
[5] Integration Protocol Default (ON)
[6] Interactive Protocol SMA Default (OFF)
[7] Reserved
[8] Interactive Encryption for SMA Default (ON)
[426] Session 1 Integration Toggle Options 3
The toggle options in this section are used to determine the polling and notification behavior used for integration with third
party applications.
[1] UDP Polling Default (OFF)
[2] TCP Polling Default (OFF)
[3] Real-time Notification Default (OFF)
[4] Notification Follows Poll Default (OFF)
[5] Reserved
[6] Reserved
[7] Reserved
[8] Reserved
[427] Session 1 Interactive Polling Interval in Seconds
Default (000A)
This option controls the polling interval from the alarm panel to the integration interface for the purpose of optimizing data
usage. The shorter the interval, the higher the data usage.
Valid range: 0000-FFFF
[428] Session 1 Integration Server IP
This section displays the IP address of the third party server. Do not program this section if a domain name is programmed
in setion [431].
[429] Session 1 Integration Notification Port
Default (0C00/3072)
This section is used to program the TCP Integration port for real time notification.
[430] Session 1 Integration Polling Port
Default (0C01/3073)
This section is used to program the integration server port. Refer to third party device manual for more information.
34

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents