[2] Serial Communication Port Enabled Default (OFF)
[3] SMS Command and Control Default (ON)
[4] Interactive Default (OFF)
[5] SMS Character Format Default (OFF )
ON: SMS Unicode, maximum message length is 70 characters.
OFF: 7 bit SMS, maximum message length is 160 characters.
[6] Long SMS Message Handling Default (OFF)
ON: If maximum message length is exceeded, it is split and sent as multiple SMS messages.
OFF: If maximum message length is exceeded, a single, truncated SMS message is sent.
[7] Reserved
[8] Reserved
[308] Outgoing SMS Retry Attempts
Default (19) Valid entries are 00 - FF.
The default value is 25 attempts. If the communicator is having difficulty delivering an SMS message, it shall send the mes-
sage again up until the number of retry attempts has been met.
[309] Outgoing SMS Retry Counter
Default (0005) Valid entries are 0000 - FFFF.
If the communicator is unable to deliver an SMS message, it will wait the number of seconds programmed in this section
before attempting to resend the message.
[311]-[342] SMS Phone Number 1-32
Default (   )
These sections may be programmed through DLS or the keypad. Up to 32 SMS telephone numbers (4-32 digits) can be
programmed in sections [311]-[342]. Leaving programming blank for a telephone number will disable that number. The
user can program their own mobile telephone numbers at the keypad using [*] [6] < > "SMS Programming". The SMS com-
mand and control feature uses the SMS messaging service provided by the cellular network and is subject to the limitations
of SMS messaging. These limitations include delayed messages and lack of guaranteed delivery.
NOTE: SMS command and control (sections [601]-[618]) will only process messages from mobile telephone numbers pro-
grammed in this section if SMS command and control is enabled ([301][3] ON). SMS responses are listed in sec-
tions [621]-[630]. A blank telephone number is disabled.
[343]-[374] SMS Phone Number 1-32 Toggle Options
The toggles in this section determine the type of event message that will be sent to the SMS number programmed in sec-
tions [311]-[342].
[1] SMS Notification Alarm/Restore Default (ON)
[2] SMS Notification Tamper/Restore Default (ON)
[3] SMS Notification Opening/Closing Default (ON)
[4] SMS Notification System Maintenance Default (ON)
[5] SMS Notification System Test Default (ON)
[6] SMS Notification Internal Events Default (ON)
[7] SMS Notification Enabled Default (ON)
[8] SMS Command and Control Enabled Default (ON)
[375]-[406] SMS Phone Number 1-32 Partition Option
Default (00)
01-32 assigns the phone number to a partition. 01 signifies partition 1 and 32 signifies partition 32.
FF disables partition assigning for the phone number.
00 is for global partitioning. The phone number will receive notifications from all partitions.
[420] Serial Port Baud Rate (for use with 'R' models only)
Default (05)
Valid entries are 01 - 05:
01 = 9600 Baud
02 = 19200 Baud
03 = 38400 Baud
04 = 57600 Baud
05 = 115200 Baud
[421] Serial Port Settings (for use with 'R' models only)
[1] Parity Enabled Default (OFF)
ON: Parity
OFF: No Parity
33