Minimum Opening For Masonry & Zc Fireplaces; Hearth Extension; Floor Protection - Quadra-Fire TREKKERI-MBK TREKKERI-CSB TREKKERI-PMH Installation Manual

Table of Contents

Advertisement

TREKKER INSERT
Built-In Vertical
24-5/16 in
(618mm)
16
(406mm)
Figure 10.1
41-3/4
1060mm
CANADA 15-1/8 (537mm)
Figure 10.2

HEARTH EXTENSION

No thermal protection required
Ember protection only!
*If mantel depth is 10 inches or less, than the height from
the hearth to the bottom of the mantel is 39-3/4 inches.
If employing a hearth extension, any parts or materials
used in construction must be non-combustible.
10
TOP TRIM
18-5/16 in
(465mm)
HEARTH
EXTENSION
MANTEL
12in max *
USA 15-1/8
C. Minimum Opening for Masonry & ZC
Fireplaces
29-3/4 in
(1010mm)
Figure 10.3
Minimum Opening
Dimensions
A
Height
Front Width (Steel Panel
Set)
B
Front Width (Cast Panel
Set)
C
Back Width
Depth (Steel Panel Set)
D
Depth (Cast Panel Set)
D. Hearth Extension
Use a non-combustible ember floor protector, extending
beneath the appliance and to the front, and to the sides as
indicated in sub-section E. Floor Protection.
E. Floor Protection
Figure 10.4
7082-153D
A
D
C
B
Inches
24-3/8
32-1/4
32-1/4
24-1/8
16-5/8
16-1/4
D
B
September 27, 2018
Millimeters
619
819
819
613
422
413