B. Minimum Height of Flue System Exit
6000mm
increase as necessary until nothing
within 3000mm of fluetop
any nearby structure
Figure 13.1
NOTICE:
• Chimney performance may vary.
• Trees, buildings, roof lines and wind conditions
affect performance.
• Chimney height may need adjustment if smoking or
overdraft occurs.
13
3000mm
more than 3000mm
or less
600mm
minimum
NOTICE: Locating the appliance in a basement or in
a location of considerable air movement can cause
intermittent smoke spillage from appliance. Do not locate
appliance near
• Frequently open doors
• Central heat outlets or returns
7037-806A
3000mm
increase from
1000mm minimum
until clear within
3000mm of flue top
05/21