Second Edition First Printing

Work Area Safety

Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or proximity
to electrical current.
Obey all local and
governmental regulations
regarding required
clearance from electrical
power lines. At a minimum,
the required clearance
contained in the chart
below must be followed.
Line Voltage
0 to 50KV
50 to 200KV
200 to 350KV
350 to 500KV
500 to 750KV
750 to 1000KV
Allow for platform movement, electrical line sway or
sag, and beware of strong or gusty winds.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Part No. 1261387
Required Clearance
3.05 m
4.60 m
6.10 m
7.62 m
10.67 m
13.72 m
Keep away from the
machine if it contacts
energized power lines.
Personnel on the ground
or in the platform must not
touch or operate the
machine until energized
power lines are shut off.
S-100HD • S-120HD
Work Area Safety
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity.
Maximum platform capacity
Maximum occupants
The weight of options and accessories, such as
pipe cradles, panel cradles and welders, will reduce
the rated platform capacity and must be subtracted
from the platform capacity. See the decals with the
options and accessories.
If using accessories, read, understand and obey
the decals, instructions and manuals with the
accessory.
Do not depend on the tilt alarm as a level indicator.
The tilt alarm sounds in the platform only when the
machine is on a severe slope.
Operator's Manual
340 kg
Do not raise or extend the
boom unless the machine
is on a firm, level surface.
2
9