Electrocution Hazards
Line Voltage
0 to 50KV
50KV to 200KV
200KV to 350KV
350KV to 500KV
500KV to 750KV
750KV to 1000KV
Allow for platform movement, electrical line sway
or sag and beware of strong or gusty winds.
Part No. 1261388
This machine is not
electrically insulated
and will not provide
protection from contact
with or proximity to
electrical current.
Maintain safe
distances from
electrical power
lines and apparatus
in accordance
with applicable
governmental
regulations and the
following chart.
Required Clearance
3.0 m
4.6 m
6.1 m
7.6 m
10.6 m
13.7 m
S-100 • S-105 • S-120 • S-125

Work Area Safety

Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity.
Maximum platform capacity
S-100
S-105
S-120
S-125
Maximum occupants
Operator's Manual
Keep away from the
machine if it contacts
energized power
lines. Personnel
on the ground or in
the platform must
not touch or operate
the machine until
energized power lines
are shut off.
Do not use the
machine as a ground
for welding unless the
machine is equipped
with the weld line to
platform option and it is
properly connected.
340 kg
227 kg
340 kg
227 kg