Installation
Install the automatic applicator as follows:
•
mount the automatic dispense valve
•
attach dispense tip or nozzle
•
connect the air lines
•
connect material hose
•
if heated, connect the electrical cable
•
if temperature conditioned, connect the water
circulation
•
make sure the automatic dispense valve is
grounded
Ambient or temperature conditioned model shown
Fig. 1 ______________________________________
309376L
Water
Fluid
Circulation
Inlet
Ports
Mounting
Holes
TI1377A
Mount the Automatic Dispense Valve
Mount the automatic dispense valve to the mounting
bracket on a stationary support or robotic arm (Fig. 1),
using two M6x1.0 socket head screws and two flat
washers. If your application is heated, be sure to
position the insulation block between the dispense valve
and the mounting bracket, (Fig. 2). Refer to the
dimensions on page 32.
7