Back pressure valve

Advertisement

Typical Installation
KEY
A
Fluid Pressure Regulator
B
Air Spray Gun
C
Fluid Return Line
D
Back Pressure Valve
E
Air Supply Line
F
Fluid Supply Line
CAUTION
Before installing the valve, check the tightness of the
capscrews (4). The screws might be loose before the
valve is installed and put under pressure. See the
Parts Drawing for the tightening sequence and
torque value. After 24 hours, or if the valve leaks
during operation, check and torque the screws again.
4
306770

Installation

A
B
Install the valve in the spray gun return line (See the
Typical Installation). Connect the line to the 1 in.
npt(f) inlet and outlet. Make sure flow agrees with IN
and OUT markings on the valve body.
If more than one spray station is used, the back pres-
sure valve should be installed in the supply line after
the last station to maintain proper circulating pressures
in the system.
E
C
F
D
7867