Technical Data - Graco EnDure Instruction Manual

Automatic dispense valves
Hide thumbs Also See for EnDure:
Table of Contents

Advertisement

Technical Data

Maximum working fluid pressure
Maximum static fluid pressure
Maximum working dry air pressure
Maximum working temperature
Standard seals in models 244535, 244910,
244961, 244962
High temperature seals in models 244907,
244908, 244909, 244937, 244951, 245184
Material Inlet on inlet manifold (all models)
Air Inlets (open and close)
120 Volt Heater
240 Volt Heater
RTD Sensor
Weight (automatic dispense valve + manifold)
Model 244910 can be temperature conditioned with circulating water. The valve/manifold is equipped with:
(1) 1/4 npt(f) water inlet
(4) 1/8 npt(f) water outlets
(2) 1/8 npt(f) ports that can be used for a temperature sensor (see page 30).
WETTED PARTS (all valves)
Aluminum, Stainless Steel, chrome, carbide, acetal plastic, PTFE, fluoroelastomer
PRIMARY SEAL MATERIALS
Model 244535 - Polymyte
Models 244907 and 244937 - graphite fiber reinforced PTFE (black) high temperature
Material Outlet
244951 and 245184
244910, 244961, 244962,
244908, 244909
Polymyte is a trademark of Parker Seal.
34
(120 Volt models - pins A and B)
(240 Volt models - pins 3 and 4)
®
(orange) standard temperature
1/2 npt(m)
5/8–18 with nut to accept
1/8 npt nozzles
24.1 MPa (241 bar, 3500psi)
34.5 MPa (345 bar, 5000 psi)
150w @ 120 VAC, 96 ohms +/-10
200w @ 240 VAC, 288 ohms +30/-40
100 Ohm platinum RTD, 0.00385 ohm/ohm/deg C
(108.2 ohms @ 21° C (70° F))
.83 MPa (8.3 bar,120 psi)
95°C (200°)
204°C (400°)
1/2" npt(f)
1/8" npt
pins C and F
pins 1 and 2
approx. 1.8 kg (4 lbs)
309376L