Table 32. Library error codes (continued)
Code (H)
Description
Sensor error #2.
Accessor encoder sensor A error
00F1
detected during blink check.
Suspect the accessor encoder
sensor A.
Sensor error #3.
X encoder sensor error detected
00F2
during blink check. Suspect the X
encoder sensor.
Sensor error #4.
Magazine sensor error detected
00F3
during blink check. Suspect the
magazine sensor.
Sensor error #5.
X origin sensor error detected
00F8
during blink check. Suspect the X
origin sensor.
Sensor error #6.
Cartridge sensor error detected
00F9
during blink check. Suspect the
cartridge sensor.
Sensor error #7.
accessor forward sensor error
00FA
detected during blink check.
Suspect the accessor forward
sensor.
Sensor error #8.
accessor origin sensor error
00FB
detected during blink check.
Suspect the accessor origin sensor.
196
IBM TS2900 Tape Autoloader: Setup, Operator, and Service Guide Machine Type 3572
Panel Indication
Cycle the power supply and try again.
v If the problem is corrected, run Library Verify
before normal library operations resume.
CHK 00F1
v If the problem persists, see "Contacting IBM
technical support" on page 139.
CHK 00F2
CHK 00F3
CHK 00F8
CHK 00F9
CHK 00FA
CHK 00FB
Action Required