Table 32. Library error codes (continued)
Code (H)
Description
Information acquisition from the
0010
DHCP server failed.
Time acquisition from the NTP
0011
server failed.
LDI I/F error.
0020
Transmit data abnormality
detected (NAK reception).
LDI I/F error.
0021
Receive timeout detected
(ACK/NAK reception).
LDI I/F error.
0022
Response packet reception
timeout detected.
LDI I/F error.
0023
ENQ receive timeout detected.
LDI I/F error.
0024
Receive data abnormality
detected.
0029
LDI command ends abnormally.
Commands to the Encryption Key
002A
Manager over the retry limit.
188
IBM TS2900 Tape Autoloader: Setup, Operator, and Service Guide Machine Type 3572
Panel Indication
1. Observe LEDs. See "Interpreting front panel
LEDs" on page 136.
2. Confirm the DHCP server settings.
3. Reseat all cables. See "Reseating cables" on
page 137.
-
4. Cycle the power supply and try again.
v If the problem is corrected, run Library
Verify before normal library operations
resume.
v If the problem persists, see "Contacting
IBM technical support" on page 139.
1. Observe LEDs. See "Interpreting front panel
LEDs" on page 136.
2. Confirm the time server settings.
3. Reseat all cables. See "Reseating cables" on
page 137.
-
4. Cycle the power supply and try again.
v If the problem is corrected, run Library
Verify before normal library operations
resume.
v If the problem persists, see "Contacting
IBM technical support" on page 139.
1. Observe LEDs. See "Interpreting front panel
LEDs" on page 136.
-
2. Reseat all cables. See "Reseating cables" on
page 137.
3. Cycle the power supply and try again.
-
v If the problem is corrected, run Library
Verify before normal library operations
resume.
v If the problem persists, see "Contacting
-
IBM technical support" on page 139.
-
-
1. Confirm the Encryption Key Manager
settings.
-
2. Reseat all cables. See "Reseating cables" on
page 137.
3. Cycle the power supply and try again.
v If the problem is corrected, run Library
Verify before normal library operations
-
resume.
v If the problem persists, see "Contacting
IBM technical support" on page 139.
Action Required

Advertisement

Table of Contents
loading

Table of Contents