Genie GR-12 Service Manual page 62

Table of Contents

Advertisement

Section 4 • Repair Procedures
MAST COMPONENTS
How to Disassemble the Mast
Bodily injury hazard. This
procedure requires specific repair
skills, lifting equipment and a
suitable workshop. Attempting this
procedure without these skills and
tools could result in death or
serious injury and significant
component damage. Dealer
service is strongly recommended.
1 Remove the mast. See 3-1, How to Remove the
Mast Assembly.
2 Rotate the mast until the carriage is facing up.
3 Remove the socket head retaining fastener
from the clevis block on the lift cylinder rod end
at the top of the number 1 column.
a
b
c
d
a
top of number 1 column
b
clevis block (not shown)
c
clevis block fastener
d
lift cylinder (not shown)
4 - 14
4 Remove the lift cylinder barrel end mounting
fasteners.
a
5 Loosen the lift cylinder mounting bracket
fasteners.
6 Support the cylinder and carefully slide it out of
the mast assembly.
GR-12 • GR-15 • GR-20
b
c
d
a
cylinder mounting plate
b
cylinder
c
cylinder mounting bolt
d
plate mounting fasteners
Crushing hazard. The lift cylinder
could become unbalanced and fall
if not properly supported when
removed from the machine.
November 2005
REV B
Part No. 84700

Hide quick links: