Section 4 • Repair Procedures
PLATFORM CONTROLS
Machine Configuration
Code Chart
A mark in the four right columns indicates that the
machine configuration, at left, includes this option.
Machine
Function
Non-slab
Motion
Code at
Option
Alarm
Diagnostic
Display
05
23
25
26
27
29
30
31
4 - 10
Lift/Drive
Platform
Cut Out
Overload
GR-12 • GR-15 • GR-20
Machine Option Definitions
Non-slab Option: For the GR to function correctly,
each model is configured with this option.
Motion Alarm: The motion alarm will sound when
operating any function.
Lift/Drive Cut Out: In addition to an alarm
sounding, lift and drive functions are disabled when
the platform is raised above the down limit switch
and the incline of the chassis exceeds the rating on
the serial plate. Configured on all machines.
Platform Overload: When the platform overload
limit switch is tripped, signaling an overload
condition in the platform, all machine functions are
disabled. The additional weight must be removed
from the platform and the power cycled from off to
on before any function can be resumed. Required
for CE models.
Battery Drain Alarm: When the machine is turned
on and in the stowed position, and no function is
activated for 2 minutes, an alarm will sound once
every 3 seconds.
When this option is configured, a dot in the
diagnostic display window will remain continuously
illuminated when the ECM is in the 'SC' mode OR
when the platform up function is activated.
November 2005